2.4 Align the edge of the CAMERA PLATE with the
PLATFORM, and then side load the CAMERA PLATE
into the PLATFORM. Once the CAMERA PLATE is in
position an audible sound will be heard. At this point,
the CAMERA PLATE can slide forward / backward
only. To release the camera plate press the safety latch
button.
2.5 Position the CAMERA PLATE such that the camera's
C of G is directly above the centre axis of the Fluid
head, (fig. 7) then push the SIDE LOAD LOCK LEVER
into the locked position. Check that the CAMERA
PLATE is secure.
7
C of G
Camera Plate
(Arri Type)
Side Load Lock Lever
Fig. 7