Diamond 19048075 Instruction Manual - Page 4

Browse online or download pdf Instruction Manual for Commercial Food Equipment Diamond 19048075. Diamond 19048075 9 pages. Refrigerated tables

Diamond 19048075 Instruction Manual
1

INSTALLATION

1.0 POSITIONING

Remove the packaging except the support pallet. A forklift truck or pallet truck can be used to
move it to its installation site, lifting the refrigerated table making sure that it is not unbalanced.
The table must not be dragged over the floor.
The area where the table is positioned must be clear and clean, preventing the refrigerator
equipment's fan from absorbing materials, which are then deposited on the condenser's ribbing,
reducing the efficiency of the system.
Remove the pallet, taking care not to knock the unit. The table can now be levelled, screwing in or
unscrewing the legs. When it is levelled, the protection film can be removed from the stainless
steel using a blunt object, and not a cutter as it could scratch the steel.

1.1 CLEANING

Now the unit is correctly positioned, we must clean it:
The first cleaning must be carried out with water and neutral detergent. Once clean and dry, insert
the accessories in the appropriate places, as you prefer.
We recommend cleaning the outside of the unit daily with a damp cloth and following the direction
of the stainless steel's honing. Abrasive substances or those containing chlorine must not be used.
Rinse with clean water, avoiding direct water jets.
CONNECTION
1.2 GENERAL
Before connecting the refrigerated table to the socket, check that the network voltage and
frequency correspond with those indicated in the appliance's nameplate.
It is essential that the electrical installation where the table is going to be connected has
an EARTHING SOCKET, in addition to the appropriate protection of the magneto-thermal
switch and differential (we recommend 30 mA.)
Check that the section of the electricity socket is appropriate for the consumption it is going to
withstand.
It must be a Schuko type socket, as your table's cable this type (also called F type and in the EEC
7/4"), with a 4.8 mm terminal and earthing socket.
It is prohibited to extend this power cable for safety reasons.
Do not insert any elements through the fan guard or refrigerator equipment area grilles.
In units with combined condensation, it is necessary to have a drain connected to the general
sewage network, or to a recovery system. Refer the current legislation in each country.
In the case of equipment with controlled humidity or with water or combined condensation, it is
necessary to have a separate water inlet.
The place where the unit is going to be installed must be perfectly levelled.
In the start-up, ensure that there are no sources of heat nearby.
For the perfect operation of the components making up the refrigerator system, it is extremely
important that the air intakes, both from the fan situated inside the table and the air access to the
condenser not be blocked.
Clockwise to lower the unit
Anticlockwise to raise the unit
16