9. Troubleshooting
The following Troubleshooting Guide offers simple so-
lutions to common problems and explains the 2110's
Error Messages. Review this section for a possible so-
lution to your problem before contacting Chromalox.
Symptom
Power applied, display
does not light, and con-
troller does not function
Display alternates
between HI and SENS,
2110 disables control
output
Process does not heat
up
Erratic operation
Process not in control
Instrument continually
goes through power-up
reset
Probable Cause
1. No power applied
2. External fuse open
1. Open sensor
2. Out of calibration
1. No power being applied to the load
2. Load fuse open
1. Intermittent sensor connections
2. Controller failure (internal electronics)
3. External electrical noise
1. Incorrect settings
2. Thermocouple Wiring
1. Severe electrical noise
Note: For each symptom, perform correction steps in
the order listed.
1. Check power wiring and fusing
2. Power down and repower up
1. Check sensor wiring
2. Check selection switches
3. To verify that controller is at fault, re-
move the thermocouple and place a
jumper across the sensor terminals
of the 2110. If the display reads ap-
proximately ambient, then the sensor is
open. Replace the thermocouple.
4. See Section 7–Calibration
1. Verify Load LED is ON
2. Verify the heater or fuse is not open
3. Verify output limit is set to 100%
4. Verify set point is greater than process
temperature
5. Verify output wiring
1. Check sensor wiring or substitute sen-
sor simulator
2. Power down and repower up
3. Contact Chromalox
1. Check Proportional Band setting and
Automatic Reset setting
2. Check thermocouple polarity
1. Separate sensor wiring from other wir-
ing
2. Apply power line filter
3. Contact Chromalox
17
Correction Steps