Installation of clean water tip with a stand
and a stopper (Fig. 4)
Drill a hole in the sink (tabletop) with diameter of 12
mm.
Place the rubber gasket (2) in the bottom of the
stand (1)
Insert the threaded shank of the stand into the hole
in the tabletop.
At the bottom of the tabletop, put a plastic (3) and
metal lock (4) washers on the threaded shank and
screw the nut (5).
Insert the free end of the tube extending from the
clean water tip into the stand hole (1).
At the bottom of the tabletop, put the bushing (6),
and then the collet (7) on the free end of the plastic
tube. The recommended distance from the end of the
threaded shank (1) to the bushing (6) is about 600
mm.
Installation of the drain clamp (Fig. 5)
It is recommended to install the clamp on the
drainage line in front of the siphon (the drain clamp
fits to most drainage lines with diameters of about
40 mm).
Remove the protective film from the gasket (1).
Glue the gasket (1) on the inside of the clamp, so that
the gasket hole aligns with the hole in the yoke
socket.
Install the clamp on the drain line and tighten the
bolts (2).
The bolts should be tightened evenly so the two
clamps are parallel.
Drill a hole with a diameter of 7 mm through the
clamp fitting.
Put the plastic nut on the free end of the drain tube
JG (red) and insert the tube into the drain hose clamp
for 20-30 mm, then screw the nut on the fitting.
Install the manifold assembly
Fix the manifolds so that after installing of the cartridges, there is a gap of at least 50 mm between the
lowest point of the cartridges and the floor.
This is necessary for the convenience of changing the filter cartridges and installing the drainage tube.
Pay attention to the supply tubes coming through freely and without bending.
Figure 4
2
1
Figure 5
1
2
3
4
5
6
7
5