Cutter Operation

• Install the cut-off device as far as it will go into
the neck or on the wall of the container (for
example, bottles or pans).
• Ensure that the cutter is securely secured with
a latch.
• Insert the tip into the cutter hole.
• Wait for the container to fill with clean water,
disconnect the tip from it, and turn off the wa-
ter supply.
• Disconnect the isolator from the container.
• If it is necessary to stop the collection of water
into the tank ahead of schedule, just press the
button located on the end of the cutter.
Changing the replacement cartridge
The service life of the membrane cartridge (3)
directly depends on the performance of the water
treatment unit (2). Therefore, it is very important
to timely replace the filter cartridges.
Replacing K1 and K7M Cartridges
• Close the inlet valve on the connection unit
and connect the tip to the storage tank to re-
lieve pressure.
• Turn the used cartridge counterclockwise and
remove it.
• Remove the packing tape from the new
cartridge.
• Insert the new cartridge into the manifold block
until it stops and, while slightly pressing, turn
the cartridge clockwise until it clicks.
• Install the flushing plug in the middle slot (in-
stead of the membrane cartridge).
• Open the input tap on the connection node.
• Insert the tip into the slot of the cutter, holding
it above the sink.
• Holding the tip, place the cutter in the sink, then
drain the water passing through the RO-312S
Pro within 10 minutes.
• Disconnect the tip from the cutter by pressing
the key located on the end of the cutter.
• Close the inlet tap.
* Depending on the conditions of storage, transportation and operation, the time for complete washing of the membrane cartridge
may vary, but takes no more than 24 hours.
10
Clean Water Tip
Clipper slot
Shutdown key
Latch
• Remove the flushing plug and install the mem-
brane cartridge by turning the cartridge clock-
wise until it clicks.
• Open the inlet crane and make sure that the
RO-312S Pro connections are tight.
Replacing a RO-100S Cartridge
• Close the inlet tap and connect the tip to the
storage tank to relieve pressure.
• Turn the used membrane cartridge counter-
clockwise and remove it.
• Remove the packing tape from the new
cartridge.
• Insert the new cartridge into the manifold block
until it stops and, while slightly pressing, turn
the cartridge clockwise until it clicks.
• Open the inlet tap.
• Insert the tip into the slot of the cutter, holding
it above the sink.
• Holding the tip, put the cutter in the sink, then
drain the water from the water purifier within
1 hour. *
• Disconnect the tip from the cutter by pressing
the key located on the end of the cutter.
• Open the inlet crane and make sure that the
RO-312S Pro connections are tight.