Figure 5 - Air bleed tube alignment
Initial Start-Up
Do not operate
filter at more than
50 psi (345 kPa).
1. Ensure pump is OFF. Turn off any
automatic controls and lock out / tag
out switches and / or circuit breakers
to ensure the system cannot
inadvertently turn on.
Verify power is
removed from the
system. Disconnect, tag and lock out
power source before attempting to
install, service, relocate or perform any
maintenance.
2. Install the filter cartridge in the
base of the tank, being careful to
avoid the flow diverter in the inlet.
Ensure the air bleed tube is correctly
installed (Figure 5). Push down
firmly to seal the cartridge.
3. Clean the o-ring seating area on the
inside of the base (Figure 6). Lightly
lubricate with silicone based grease.
Only use silicone
based grease to
lubricate the o-ring. Other lubricants
may damage the o-ring and plastic
filter components. Do not lubricate the
threads on the tank base or the locking
ring, as they may collect debris and
hinder removal.
59719-XXXX, 59721-XXXX, 59722-XXXX, 59722-XXXX, 59723-XXXX and 59724-XXXX
Clean and lube
o-ring seating
area (shaded)
Air bleed tube
must be inside
top support
ring
Air bleed
tube must
go through
center of
cartridge
support (if
equipped)
Figure 6 - O-ring seating area
4. Inspect o-ring. Ensure the o-ring is
clean and properly seated in the
o-ring groove (Figure 7). The o-ring
should not be twisted.
be replaced.
5. Open the air relief valve by turning
it counter-clockwise two full turns.
6. Place the top assembly on the filter
base, centering it on the cartridge
and the base.
7. Turn the locking ring counter-
clockwise until the top assembly falls
into place (1/4 turn or less.)
8. Holding the locking ring stationary,
rotate the top to point the air relief
valve in a safe direction (away from
the pump and any other electrical
components.)
9. Secure the locking ring by turning it
clockwise until the safety latch clicks
into place (approximately 1/2 turn).
The latch should fall between the
two tabs on the ring (Figure 8). The
ring may be slightly loose, but it will
tighten when the pump turns on.
If the locking ring will not fully
engage the latch, turn it counter-
clockwise to remove the top
assembly and return to step 2,
ensuring the cartridge is properly
seated and the o-ring is lubricated
and properly seated.
O-ring must be
seated in this
groove
Do NOT seat
o-ring in this
groove
Figure 7 - O-ring groove
Do not remove the
o-ring unless it is to
Figure 8 - Safety latch: locked position
10. If installed, open the valves
11. Stand clear of the filter tank.
12. Once a steady stream of water flows
valve fails to seal, turn the pump off,
remove the top assembly and inspect
the valve o-ring. reseat or replace if
necessary.
13. Record the filter pressure gauge
7
Safety latch must fall between
the two tabs in the locking ring
separating the filter from the rest of
the system.
Following the pump manufacturer's
instructions, start the pump to purge
the air from the system.
from the air relief valve, close the
valve by pushing it down while
turning it clockwise. It should fully
tighten in approximately 2 turns.
Do not over-tighten
the valve. If the
reading in the "Cartridge Cleaning"
section of this owner's manual.
www.aquaprosystems.com