Diamond VT12 Installation, Operating And Maintenance Manual - Page 17

Browse online or download pdf Installation, Operating And Maintenance Manual for Commercial Food Equipment Diamond VT12. Diamond VT12 20 pages. Units with safety glass cooktop on open shelving or heated cabinets

Fig. 2: SCHEMA ELETTRICO – WIRING DIAGRAM – SCHALTPLAN - SCHEMA ELECTRIQUE
ELEMENTO CON PIANO RISCALDANTE IN CRISTALLO TEMPERATO SU ARMADIO CALDO
-
-
SAFETY GLASS COOKTOP UNIT ON HEATED CABINET
ELEMENT MIT BEHEIZTER PLATTE AUS GEHÄRTETEM KRISTALLGLAS AUF BEHEIZTEM UNTERSCHRANK
-
ELEMENT AVEC PLAN CHAUFFANT EN VERRE TREMPE SUR ARMOIRE CHAUDE
-
IGp
IGa
Ta
Ts
M
R
E1/E2
L
IGp
IGa
Ta
Ts
M
R
E1/E2
L
A010018 Rev. 4
PDF created with FinePrint pdfFactory Pro trial version
INTERRUTTORE GENERALE PIASTRE
INTERRUTTORE GENERALE ARMADIO
TERMOSTATO REGOLAZIONE ARMADIO
TERMOSTATO DI SICUREZZA
MOTORE VENTILATORE
RESISTENZA RISCALDANTE
REGOLATORE D'ENERGIA
LAMPADA SPIA
HAUPTSCHALTER PLATTEN
HAUPTSCHALTER UNTERSCHRANK
THERMOSTAT EINSTELLUNG UNTERSCHRANK
SICHERHEITSTHERMOSTAT
VENTILATORMOTOR
HEIZKÖRPER
ENERGIEREGLER
KONTROLLLAMPE
Mod. VC 12 (ECVC 12)
Mod. VC 15 (ECVC 15)
IGp
IGa
Ta
Ts
M
R
E1/E2
L
IGp
IGa
Ta
Ts
M
R
E1/E2
L
Pag. 16 di 18
http://www.fineprint.com
HOTPLATE MASTER SWITCH
CABINET MASTER SWITCH
CABINET REGULATOR THERMOSTAT
SAFETY THERMOSTAT
FAN MOTOR
HEATING ELEMENT
ENERGY REGULATOR
INDICATOR LIGHT
INTERRUPTEUR GENERAL PLAQUES
INTERRUPTEUR GENERAL ARMOIRE
THERMOSTAT REGLAGE ARMOIRE
THERMOSTAT DE SECURITE
MOTEUR VENTILATEUR
RESISTANCE CHAUFFANTE
REGULATEUR D'ENERGIE
VOYANT