Performance Data Sheet for the EQ-1000 Aquasana Whole House Rhino
Models
Replacement
EQ-1000
EQ-1000R
Manufactured by: Aquasana, Inc. 6310 Midway Road · Haltom City, Texas 76117 · 866-662-6885
This system has been independently tested according to NSF/ANSI 42 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than
or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42.
NSF/ANSI 42
Chlorine Reduction, Free Available
Data Summary Table
Sample
Accumulated
Point
Volume (gal)
Startup
10
6%
60,000
12%
120,000
18%
180,000
24%
240,000
30%
300,000
36%
360,000
42%
420,000
48%
480,000
50%
500,000
54%
540,000
60%
600,000
66%
660,000
72%
720,000
78%
780,000
84%
840,000
90%
900,000
96%
960,000
100%
1,000,000
Independent testing was performed under standard laboratory conditions, actual performance may vary. All data reported is
associated with quality control that met method, EPA, NSF/ANSI or internal laboratory specification.
For use with municipally treated water only. Do not use with water that is microbiologically unsafe or of
unknown water quality without adequate disinfection before or after the system.
• All contaminants reduced by this filter are listed.
• Not all contaminants listed may be present in your water.
• Does not remove all contaminants that may be present in tap water.
Filter is only to be used with cold water.
Filter usage must comply with all state and local laws.
Testing was performed under standard laboratory
conditions, actual performance may vary.
Max Operating pressure
Rated capacity
100 psi
1,000,000 gallons
Influent Challenge
Pressure drop
Chlorine
2.02 mg/L ±10%
10.5 psi
Chlorine, Free Available (mg/L)
Dynamic Pressure
(psi)
Influent
60
2.04
60
2.09
60
2.09
60
2.07
60
1.93
60
1.91
60
2.02
60
1.82
60
1.89
60
2.00
60
1.95
60
2.07
60
1.84
60
1.84
60
1.93
60
2.19
60
2.08
60
2.11
60
2.09
Water Filter System
®
Operating temp. range
40-90º F
Minimum
Overall %
reduction
reduction
≥50%
>97.4 %
% Reduction of
this sample
Effluent 1
ND (<0.01)
99.51%
ND (<0.01)
99.52%
ND (<0.01)
99.52%
ND (<0.01)
99.52%
ND (<0.01)
99.52%
ND (<0.01)
99.52%
ND (<0.01)
99.48%
ND (<0.01)
99.45%
ND (<0.01)
99.47%
ND (0.02)
99.00%
0.09
97.73%
0.05
97.58%
0.08
95.65%
0.08
99.54%
0.06
96.89%
ND (<0.02)
98.62%
0.06
97.12%
0.15
91.94%
0.15
92.82%
Systems certified for cyst reduction may be
used on disinfected waters that may contain
filterable cysts.
See owner's manual for general installation
conditions and needs plus manufacturer's
limited warranty.
Rated flow
7.0 gpm
Results
Pass