Before installing
• Lay out system in appropriate configuration. Improper sequence
of equipment will affect performance and could possibly damage
your system.
• Pick an appropriate installation location. Dimensions of systems vary.
– Iron Filter System with Well Water Rhino:
54" x 57" (LxH)
– Iron Filter System with Salt-Free Conditioner + Well Water Rhino:
66" x 57" (LxH)
• Install housings at appropriate height for easy filter changes.
- Iron Filter System: 30" high
- Iron Filter System + Rhino Water Filter: 37.5" high
– If attaching to a Rhino Well Water system, it should be installed at a
minimum height of 37.5" to align inlets.
• For all installations: Anticipate the need for additional parts and pieces
including but not limited to pex tubing, clamps, and mounting screws
to install unit properly (available at a local home improvement stores or
through your plumbing contractor). Due to the varieties of home design,
not all configurations can be addressed in this guide.
• DO NOT install this filter where the line pressure may exceed 100 psi.
The operating pressure range for this filter is between 20psi – 100psi.
• Install on cold water lines only 40°– 90°F (4.4º – 32.2ºC).
• Installation of the filtration system must comply with existing state and
local plumbing codes. Aquasana and its manufacturer are not liable for
consequential or incidental damages due to improper installation.
• DO NOT install the unit on its side. It must be installed upright
to maximize contact with media bed.
SYSTEM CONFIGURATION