AquaScape AQUAFORCE 5200 Instructions And Maintenance Instructions - Page 7

Browse online or download pdf Instructions And Maintenance Instructions for Water Pump AquaScape AQUAFORCE 5200. AquaScape AQUAFORCE 5200 16 pages. Solids-handling pond pump
Also for AquaScape AQUAFORCE 5200: Instructions & Maintenance (16 pages), Instructions Manual (16 pages)

AquaScape AQUAFORCE 5200 Instructions And Maintenance Instructions
• Pull off any debris stuck to the pump filter cage and/or use a
garden hose to spray off any debris stuck to the filter cage.
• Internal Pump Cleaning – if you have thoroughly cleaned
the filter cage screens and still have diminished flow rates,
then you will need to remove the pump from the lower cage
and inspect the impeller rotor assembly.
• Pull the cage release tabs outward to unlock the upper and
lower pump cages.
• With the cage tabs released, the upper filter cage can be
lifted to expose the pump.
www.aquascapeinc.com |
CAN 1-866-766-3426 |
• Remove the screws
securing the pump
restraining bracket,
allowing the pump to be
lifted from the lower cage.
• For easier pump access, pull the power cord free from the
strain relief.
• Remove the four screws that hold the water cover chamber
and inspect the impeller rotor assembly.
US 1-866-877-6637