Panasonic WV-SW396 Installation Manual
Connection
Caution:
Before starting connection, make sure that the circuit breaker is switched off. Failure to observe this may cause fire,
electric shock, injury, or damage to the product.
Power cable
8P alarm cable connector
• Power cable
Connect the power cable to the 24 V AC power supply using the 24 V AC power supply connector kit (accessory).
Important:
• The power supply of 24 V AC shall be insulated against 120 V AC (for U.S. and Canada) or 220 V - 240 V AC (for
Europe and other countries).
• Do not cut or process the network cable since the power is superimposed when using a PoE+ device for power sup-
ply. Besides, do not put an excessive weight on connected sections.
22
Brown
Blue
Green/Yellow
Network cable
Output cable for the
monitor used for
adjustment
External I/O cable
Microphone input cable (white)
Audio output cable (black)
ALARM IN1/DAY/NIGHT IN (black) (EXT I/O 1)
GND (brown)
ALARM IN2/ALARM OUT (red) (EXT I/O 2)
GND (orange)
ALARM IN3/AUX OUT (yellow) (EXT I/O 3)
GND (light blue or green)
Unused (blue)
Unused (purple)
To the power supply (24 V AC, 50 Hz/60 Hz)
GND
LAN cable (category 5e or better, STP*)
* E model only
Coaxial cable
(BNC)
8P alarm cable (accessory)
To a plug-in power type microphone
To an external powered speaker
To a PoE+ hub, PC, etc.
To the monitor used
for adjustment
To a sensor