Panasonic AG-HPX250EN Electrical Adjustment - Page 19

Browse online or download pdf Electrical Adjustment for Digital Camera Panasonic AG-HPX250EN. Panasonic AG-HPX250EN 20 pages.
Also for Panasonic AG-HPX250EN: Operating Instructions Manual (36 pages)

Panasonic AG-HPX250EN Electrical Adjustment

2-1-8. Video Output Level Adjustment

1. Connect the WFM to the VIDEO OUT with 75ohm termination.
2. Open the SYSTEM SETUP screen and set the item "SYSTEM MODE" to "1080/59.94i" (MAIN MENU >
SYSTEM SETUP > SYSTEM MODE).
3. Select "CAM(C)" section after start up the PC EVR software, and click "OK" button.
4. Select "Adjustment Tool" in "Tools(W)" menu, Adjustment Tool screen will appear on screen.
5. Click the "Start" button for Video Level Adj..
6. Adjust Luminance level "Y" by clicking the adjustment button for Y so that it is within specification.
7. Adjust Burst level "C" by clicking the adjustment button for C so that it is within specification.
Start button
8. Change the system frequency to 50Hz by clicking "50Hz<->60Hz" button on the Adjustment Tool screen.
Click the "50Hz<->60Hz" button. And click the "Re-Boot Power" button after the message "TURN POWER
OFF" is displayed on the LCD panel. The power of camera recorder is automatically OFF and ON.
9. Adjust Luminance level "Y" by clicking the adjustment button for Y so that it is within specification.
10. Adjust Burst level "C" by clicking the adjustment button for C so that it is within specification.
11. Click the "Set" button for Video Level Adj. to end of video level adjustment mode.
Start button
Set button
Adjustment button (For NTSC)
Adjustment value (For NTSC)
Adjustment button (For PAL)
Adjustment value (For PAL)
NTSC: Y = 714mV  7mV
NTSC: C = 286mV  6mV
C
Y
ELE-18
PAL: Y = 700mV  7mV
PAL: C = 300mV  6mV
Y
C