HP 201723-B21 - HP StorageWorks Modular SAN Array 1000 Hard Drive Release Note - Page 8

Browse online or download pdf Release Note for Switch HP 201723-B21 - HP StorageWorks Modular SAN Array 1000 Hard Drive. HP 201723-B21 - HP StorageWorks Modular SAN Array 1000 Hard Drive 8 pages. Storageworks modular smart array controller, cache, and battery replacement instructions
Also for HP 201723-B21 - HP StorageWorks Modular SAN Array 1000 Hard Drive: Reference Manual (48 pages), Administration Manual (40 pages), Release Note (13 pages), Quick Start Instructions (8 pages), Release Note (8 pages), Quick Start Manual (7 pages), Release Note (5 pages), Release Note (5 pages), Replacement Instructions (4 pages)

HP 201723-B21 - HP StorageWorks Modular SAN Array 1000 Hard Drive Release Note
Creating partitions on the management station: Deleting LUNs presented to the management station
may cause errors if new LUNs are created immediately after the old LUNs are deleted. The new
LUNs may not be initialized and a drive letter not assigned.
Workaround: Reboot the management station after deleting any LUNs that were presented to the
management station. Then, perform the template deployment or creation of any new LUNs.
8