Control Operation During A Power Failure
In the event of a power failure, the valve will keep track of the time and day for 48 hours. The programmed settings are
stored in a non-volatile memory and will not be lost during a power failure. If power fails while the unit is in regeneration,
the valve will finish regeneration from the point it is at once power is restored. However, since the unit did not complete
its regeneration, it will queue another regeneration at the next scheduled regeneration time. If the valve misses a
scheduled regeneration due to a power failure, it will queue a regeneration at the next regeneration time once power is
restored.
General Installation
Water Pressure
Electrical Supply
Existing Plumbing
Unit Location
Bypass Valves
Plumbing
Figure 6. Piping Diagram
1. Locate the carbon tank, softener tank, and brine tank close to a drain where the system will be installed. The surface
should be clean and level.
2. Perform all plumbing according to local plumbing codes.
Use a ½" minimum pipe or tubing size for the drain line
Use a ¾" pipe or tubing for backwash flow rates that exceed 7 gpm or length that exceeds 20ft (6 m)
ON COPPER PLUMBING SYSTEMS BE SURE TO INSTALL A GROUNDING WIRE BETWEEN THE INLET AND OUTLET
PIPING TO MAINTAIN GROUNDING.
3. Any solder joints near the valve must be done before connecting any piping to the valve. Always leave at least 6" (152
mm) between the valve and joints when soldering pipes that are connected to the valve. Failure to do this could cause
damage to the valve.
4. If the valve is not installed on the tank, cut the 1" central pipe flush with top of each tank. Lubricate the large o-ring on
the valve that seals against the tank. Screw the valve on to the tank. Be careful to not cross thread the valve into the
tank. Only use silicone lubricant.
5. Connect the drain line to the valve.
6. Connect the brine line from the valve to the air check / safety elbow as per figure 7. Double check to make sure all
connections are assembled correctly and the brass and plastic nuts are tight and secure to prevent leaks.
7. Add water until there is approximately 1" (25 mm) of water above the grid plate. If the tank does not have a grid, add
water until it is above the air check in the brine tank. Do not add salt to the brine tank at this time.
8. Place the unit in the bypass position.
9. Slowly turn on the main water supply.
Minimum 25 PSI
Uninterrupted AC
Free of any deposits or build-ups inside pipes.
Locate close to drain and connect according to plumbing codes
Always provide for bypass valve if unit is not equipped with one.
Softener and or other water treatment equipment should be
installed to local plumbing codes
CAUTION
To Outside Faucet
Cold (Soft Water)
Hot (Soft Water)
Do not exceed 120 psi water pressure.
Do not exceed 110°F water temperature.
Do not subject unit to freezing
conditions.
Cold (Raw Water)
Cold (Filtered Water)
In
Softener
Tank
Out
Water Heater
Cold (Raw Water)
Out
In
Carbon