HP ProCurve 1600M Installation Manual - Page 21

Browse online or download pdf Installation Manual for Switch HP ProCurve 1600M. HP ProCurve 1600M 28 pages. Redundant power supply
Also for HP ProCurve 1600M: Specification Sheet (12 pages), Read Me First (8 pages), Reviewer's Manual (27 pages), Supplementary Manual (2 pages), Supplementary Manual (2 pages), Installation Manual (36 pages), Installation Manual (28 pages), Quick Setup Manual (2 pages), Quick Setup Manual (4 pages), User Manual (8 pages), Manual Supplement (28 pages), Read Me First (16 pages), Installation And Removal (2 pages), Installation Manual (12 pages), Planning And Implementation Manual (40 pages), Product End-Of-Life Disassembly Instructions (2 pages), Installation Manual (46 pages), Diagnostics Manual (2 pages), Disassembly Instructions (2 pages)

HP ProCurve 1600M Installation Manual
Tip
Number
Problem
™
The network
connection is not
working properly.
Try the following procedures:
• For the indicated port, verify that both ends of the cabling, at the switch and
the connected device, are securely connected.
• Verify the connected device and switch are both powered on and operating
correctly.
• Verify that you have used the correct cable type for the connection.
– for twisted-pair connections, in general, for connecting to an end node (MDI
port), use "straight- through" cable; for connecting to MDI-X ports on hubs
or other switches, use "crossover" cable.
Note: For the 10/100-TX GL Module and the 100/1000-T GL Module in the
default configuration (Auto), the modules automatically negotiate
whether each port operates as MDI or MDI-X, depending on the cable
type and the connected device's operation, and either a straight-
through or crossover cable can be used. If the module configuration is
changed to one of the fixed configuration options though (for example,
100-Full Duplex), then the port operates as MDI-X only and the above
statement about straight-through and crossover cables applies.
– for fiber-optic connections, verify that the transmit port on the switch is
connected to the receive port on the connected device, and the switch
receive port is connected to the transmit port on the connected device.
• For a 1000 Mbps connection, verify that the network cabling complies with the
IEEE 802.3ab standard. The cable should be installed according to the ANSI/
TIA/EIA-568-A-5 specifications. Cable testing should comply with the stated
limitations for Attenuation, Near-End Crosstalk, Far-End Crosstalk, Equal-Level
Far-End Crosstalk (ELFEXT), Multiple Disturber ELFEXT, and Return Loss.
The cable verification must include all patch cables from any end devices,
including the switch, to any patch panels in the cabling path.
• Verify that the port has not been disabled through a switch configuration
change.
You can use the console interface, or, if you have configured an IP address
on the switch, use the web browser interface, or HP TopTools for Hubs &
Switches network management software to determine the state of the port
and re-enable the port if necessary.
• If the other procedures don't resolve the problem, try using a different port or
a different cable.
Solution
Troubleshooting
15