HP ProCurve 2610-48-PWR Specifications - Page 4

Browse online or download pdf Specifications for Switch HP ProCurve 2610-48-PWR. HP ProCurve 2610-48-PWR 10 pages. Procurve switch 2610 series

HP ProCurve 2610-48-PWR Specifications
HP ProCurve Switch 2610 Series

Specifications

Ports
Physical characteristics
Dimensions
Weight
Memory and processor
Processor
Mounting
Performance
100 Mb Latency
1000 Mb Latency
Throughput
Routing/Switching capacity
MAC address table size
Environment
Operating temperature
Operating relative humidity
Non-operating/Storage temperature
Non-operating/Storage relative humidity
Altitude
Acoustic
Electrical characteristics
Maximum heat dissipation
Voltage
Current
HP ProCurve Switch 2610-48 (J9088A)
48 auto-sensing 10/100 ports (IEEE 802.3
Type 10Base-T, IEEE 802.3u Type
100Base-TX); Media Type: Auto-MDIX;
Duplex: half or full
1 RJ-45 serial console port
2 auto-sensing 10/100/1000 ports (IEEE
802.3 Type 10Base-T, IEEE 802.3u Type
100Base-TX, IEEE 802.3ab Type
1000Base-T); Duplex: 10Base-T/100Base-TX:
half or full; 1000Base-T: full only
2 open mini-GBIC (SFP) slots
9.3(d) x 17.4(w) x 1.73(h) in. (23.62 x 44.2 x
4.39 cm) (1U height)
10.75 lb. (4.88 kg), Fully loaded
MIPS @ 300 MHz, 16 MB flash, 128 MB
SDRAM; packet buffer size: 2 MB
Mounts in an EIA-standard 19 in. telco rack or
equipment cabinet (hardware included);
horizontal surface mounting only
< 6.2 µs (LIFO)
< 4.4 µs (LIFO)
up to 13.0 million pps
17.6 Gbps
8000 entries
32ºF to 122ºF (0ºC to 50ºC)
15% to 95% @ 104ºF (40ºC), non-condensing
-40ºF to 158ºF (-40ºC to 70ºC)
15% to 90% @ 149ºF (65ºC), non-condensing
up to 10000 ft. (3 km)
Power: 45 dB, Pressure: 36.2 dB; DIN
45635T.19 per ISO 7779
285 BTU/hr (300.67 kJ/hr)
100-127 / 200-240 VAC
1.3 / 0.8 A
HP ProCurve Switch 2610-24 (J9085A)
24 auto-sensing 10/100 ports (IEEE 802.3
Type 10Base-T, IEEE 802.3u Type
100Base-TX); Media Type: Auto-MDIX;
Duplex: half or full
1 RJ-45 serial console port
2 auto-sensing 10/100/1000 ports (IEEE
802.3 Type 10Base-T, IEEE 802.3u Type
100Base-TX, IEEE 802.3ab Type
1000Base-T); Duplex: 10Base-T/100Base-TX:
half or full; 1000Base-T: full only
2 open mini-GBIC (SFP) slots
9.3(d) x 17.4(w) x 1.73(h) in. (23.62 x 44.2 x
4.39 cm) (1U height)
5.5 lb. (2.49 kg), Fully loaded
MIPS @ 300 MHz, 16 MB flash, 128 MB
SDRAM; packet buffer size: 1 MB
Mounts in an EIA-standard 19 in. telco rack or
equipment cabinet (hardware included);
horizontal surface mounting only
< 4.1 µs (LIFO)
< 2.9 µs (LIFO)
up to 9.5 million pps
12.8 Gbps
8000 entries
32ºF to 122ºF (0ºC to 50ºC)
15% to 95% @ 104ºF (40ºC), non-condensing
-40ºF to 158ºF (-40ºC to 70ºC)
15% to 90% @ 149ºF (65ºC), non-condensing
up to 10000 ft. (3 km)
Power: 0 dB, Pressure: 0 dB No Fan
142 BTU/hr (149.81 kJ/hr)
100-127 / 200-240 VAC
0.8 / 0.4 A
HP ProCurve Switch 2610-24-PWR
(J9087A)
24 auto-sensing 10/100 ports (IEEE 802.3
Type 10Base-T, IEEE 802.3u Type
100Base-TX); Media Type: Auto-MDIX;
Duplex: half or full
1 RJ-45 serial console port
2 auto-sensing 10/100/1000 ports (IEEE
802.3 Type 10Base-T, IEEE 802.3u Type
100Base-TX, IEEE 802.3ab Type
1000Base-T); Duplex: 10Base-T/100Base-TX:
half or full; 1000Base-T: full only
2 open mini-GBIC (SFP) slots
12.5(d) x 17.4(w) x 1.73(h) in. (31.75 x 44.2 x
4.39 cm) (1U height)
15.05 lb. (6.83 kg), Fully loaded
MIPS @ 300 MHz, 16 MB flash, 128 MB
SDRAM; packet buffer size: 1 MB
Mounts in an EIA-standard 19 in. telco rack or
equipment cabinet (hardware included);
horizontal surface mounting only
< 4.1 µs (LIFO)
< 2.9 µs (LIFO)
up to 9.5 million pps
12.8 Gbps
8000 entries
32ºF to 122ºF (0ºC to 50ºC)
15% to 95% @ 104ºF (40ºC), non-condensing
-40ºF to 158ºF (-40ºC to 70ºC)
15% to 90% @ 149ºF (65ºC), non-condensing
up to 10000 ft. (3 km)
Power: 64 dB, Pressure: 57 dB; DIN
45635T.19 per ISO 7779
410 BTU/hr (432.55 kJ/hr), (switch-only
BTU/hr: 410; combined switch + max. PoE
devices at 15.4 W: 2281 BTU/hr )
100-127 / 200-240 VAC
7.0 / 3.5 A
4