Also for HP StorageWorks 8B - FC Entry Switch: Update Manual (9 pages), Installation Instructions Manual (20 pages), User Manual (22 pages), Firmware Release Notes (14 pages), Release Note (26 pages), Manual (50 pages), User Manual (44 pages), User Manual (44 pages), User Manual (38 pages), User Manual (38 pages), User Manual (37 pages), User Manual (30 pages), Release Note (16 pages)

HP StorageWorks 8B - FC Entry Switch Installation Manual
Installing the Switch in a Rack Using the SAN Switch Universal Rack Mount Kit
Note:
is installed in the HP System/e rack. The plenum is not needed if the switch is installed
in an HP 9000 Series or comparable EIA rack.
Verify that the plenum (part number A7346-00001) is preinstalled on the SAN Switch
2/8 before proceeding. The plenum is required for the SAN Switch 2/8 rack mount
only, as it allows air to dissipate at the rear of the rack, preventing overheating.
If the plenum is not preinstalled on the SAN Switch 2/8, refer to the HP StorageWorks
SAN Switch 2/8 Version 3.1.x Installation Guide for complete plenum installation
instructions.
Figure 8: Assembling the inner rails on a SAN Switch 2/8 with plenum
10
Addendum Pg
b. For the SAN Switch 2/8, assemble the two inner rails (one on each side)
to the switch and plenum using the appropriate number (from
#8-32 x 3/16-inch Phillips pan-head screws as shown in
The plenum is only a required part of this installation when the SAN Switch 2/8
HP StorageWorks SAN Switch 2/8|16|32 Installation Guide
step
5) of
Figure
8.