Also for HP StorageWorks XP10000 - Disk Array: Release Note (13 pages), Administrator's Manual (50 pages), Configuration Manual (42 pages), Configuration Manual (40 pages), Configuration Manual (40 pages), Configuration Manual (36 pages), Configuration Manual (36 pages), Configuration Manual (30 pages), Configuration Manual (36 pages), Release Note (5 pages), System Configuration Manual (49 pages), System Configuration Manual (42 pages), System Configuration Manual (35 pages), Configuration Manual (46 pages), Configuration Manual (46 pages), Configuration Manual (40 pages), Configuration Manual (44 pages), Configuration Manual (38 pages), Configuration Manual (34 pages), Configuration Manual (30 pages), Configuration Manual (30 pages), Configuration Manual (42 pages), User Manual (30 pages)

HP StorageWorks XP10000 - Disk Array System Configuration Manual
Example
For an OPEN-V CVS volume with capacity = 49 MB:
# of cylinders = ↑49 × 16/15↑ = ↑52.26↑
(rounded up to next integer) = 53 cylinders
OPEN-3/8/9/E: The number of cylinders for a CVS LUSE volume = # of cylinders = ↑
(capacity (MB) specified by user) × 1024/720 ↑ × n
Example
For a CVS LUSE volume with capacity = 37 MB and n = 4:
# of cylinders = ↑37 × 1024/720↑ × 4 = ↑52.62↑× 4 = 53 × 4 = 212
OPEN-V: The number of cylinders for a CVS LUSE volume = # of cylinders = ↑ (capacity
(MB) specified by user) × 16/15 ↑ × n
Example
For an OPEN-V CVS LUSE volume with capacity = 49 MB and n = 4:
# of cylinders = ↑49 × 16/15↑ × 4 = ↑52.26↑× 4 = 53 × 4 = 212
Note 6:
The capacity of an OPEN-3/8/9/E CVS volume is specified in MB, not number of
cylinders. The capacity of an OPEN-V CVS volume can be specified in MB or number
of cylinders. You set the volume size using Remote Web Console, Command View or
Command View Advanced Edition.