Also for HP StorageWorks XP10000 - Disk Array: Release Note (13 pages), Administrator's Manual (50 pages), Configuration Manual (42 pages), Configuration Manual (40 pages), Configuration Manual (40 pages), Configuration Manual (36 pages), Configuration Manual (36 pages), Configuration Manual (30 pages), Configuration Manual (36 pages), Release Note (5 pages), System Configuration Manual (49 pages), System Configuration Manual (43 pages), System Configuration Manual (42 pages), Configuration Manual (46 pages), Configuration Manual (46 pages), Configuration Manual (40 pages), Configuration Manual (44 pages), Configuration Manual (38 pages), Configuration Manual (34 pages), Configuration Manual (30 pages), Configuration Manual (30 pages), Configuration Manual (42 pages), User Manual (30 pages)

HP StorageWorks XP10000 - Disk Array System Configuration Manual

Fibre address

In fabric environments, the port addresses are assigned automatically. In arbitrated
loop environments, set the port addresses by selecting a unique arbitrated loop
physical address (AL-PA) or loop ID for each port. For specific values, refer to the HP
StorageWorks LUN Configuration and Security Manager XP User Guide applicable
to your array .

Fabric and connection parameter settings

Set each array port to FABRIC ON or OFF with connections of POINT-TO-POINT or
FC-AL as shown in the following figures and table. HP recommends that the individual
Fibre Channel paths from the NonStop host to the array be routed through separate FC
switches utilizing WWN zoning. See the HP StorageWorks SAN Design Reference
Guide at http://h18006.www1.hp.com/storage/saninfrastructure.html.