HP StorageWorks XP10000 - Disk Array Configuration Manual - Page 11

Browse online or download pdf Configuration Manual for Switch HP StorageWorks XP10000 - Disk Array. HP StorageWorks XP10000 - Disk Array 44 pages. Cache lun xp
Also for HP StorageWorks XP10000 - Disk Array: Release Note (13 pages), Administrator's Manual (50 pages), Configuration Manual (42 pages), Configuration Manual (40 pages), Configuration Manual (40 pages), Configuration Manual (36 pages), Configuration Manual (36 pages), Configuration Manual (30 pages), Configuration Manual (36 pages), Release Note (5 pages), System Configuration Manual (49 pages), System Configuration Manual (43 pages), System Configuration Manual (42 pages), System Configuration Manual (35 pages), Configuration Manual (46 pages), Configuration Manual (46 pages), Configuration Manual (40 pages), Configuration Manual (38 pages), Configuration Manual (34 pages), Configuration Manual (30 pages), Configuration Manual (30 pages), Configuration Manual (42 pages), User Manual (30 pages)

HP StorageWorks XP10000 - Disk Array Configuration Manual
CAUTION:
The correct host mode must be set for all new installations (newly connected ports) to Novell NetWare
hosts. Do not select a mode other than 0A for Novell NetWare. The host modes must be set for certain
middleware environments (for example, Novell High Availability Server, NHAS, System Fault Tolerance,
SFT III). Changing a host mode after the host has been connected is disruptive and requires the server
to be rebooted.
When a new host group is added, additional host group modes (host mode options) can be configured.
The storage administrator must verify if an additional host group mode is required for the host group.
CAUTION:
Changing host group modes for ports where servers are already installed and configured is disruptive
and requires the server to be rebooted.
XP Disk Array Configuration Guide: Novell NetWare
11