Also for HP StorageWorks XP12000: Release Note (13 pages), Administrator's Manual (50 pages), Configuration Manual (42 pages), Configuration Manual (40 pages), Configuration Manual (40 pages), Configuration Manual (36 pages), Configuration Manual (36 pages), Configuration Manual (30 pages), Configuration Manual (36 pages), Release Note (5 pages), System Configuration Manual (49 pages), System Configuration Manual (43 pages), System Configuration Manual (42 pages), System Configuration Manual (35 pages), Configuration Manual (46 pages), Configuration Manual (46 pages), Configuration Manual (40 pages), Configuration Manual (44 pages), Configuration Manual (38 pages), Configuration Manual (34 pages), Configuration Manual (30 pages), Configuration Manual (42 pages), Configuration Manual (50 pages), User Manual (30 pages)

HP StorageWorks XP12000 Configuration Manual

2 Troubleshooting

This section includes resolutions for various error conditions you may encounter.
If you are unable to resolve an error condition, ask your HP support representative for assistance. See
"Calling the HP support

Error conditions

Depending on your system configuration, you may be able to view error messages (R-SIMS) as follows:
In XP Remote Web Console (Status tab)
In XP Command View Advanced Edition ("Alerts" panel)
In XP Command View (Event History or Event Notification panels)
NOTE:
For host error conditions, refer to the NonStop Technical Library (NTL) website:
http://h30163.www3.hp.com/ntl/.
Table 4 Error conditions
Error Condition
The logical devices are not recognized
by the host.
Physical volumes cannot be created.
Logical volumes cannot be created.
The disk array responds "Not Ready"
or the disk array has displayed "Not
Ready" and timed out.

Calling the HP support center

If you are unable to resolve an error condition, contact the HP support center for assistance.
center" on page 19.
Recommended Action
Verify that the READY indicator lights on the disk array are ON.
Verify that fiber cables are correctly installed and firmly connected.
Verify that the WWNs configured in each host group match the
WWNs for the appropriate FCSA port. Do not install two devices
with the same ID on the same bus. Verify that the disk array host
mode is set correctly for the NonStop host group on the port.
Verify that the disk array logical devices are correctly formatted.
Verify that the volume capacity for OPEN-x volumes is not greater
than the maximum capacity allowed. See the
specifications" on page 23 table.
Contact HP.
XP Disk Array Configuration Guide for NonStop
"Emulation