Also for HP XP20000/XP24000: Release Note (13 pages), Integration Manual (29 pages), Release Note (4 pages), Administrator's Manual (50 pages), Configuration Manual (40 pages), Configuration Manual (40 pages), Configuration Manual (36 pages), Configuration Manual (36 pages), Configuration Manual (30 pages), Configuration Manual (36 pages), Release Note (5 pages), Configuration Manual (46 pages), Configuration Manual (46 pages), Reference Manual (46 pages), Configuration Manual (40 pages), Configuration Manual (44 pages), Configuration Manual (38 pages), Configuration Manual (34 pages), Configuration Manual (30 pages), Configuration Manual (30 pages)

HP XP20000/XP24000 Configuration Manual
mpxio-disable="no";
For all Solaris releases, add the following lines:
device-type-scsi-options-list =
"HP
OPEN", "symmetric-option";
symmetric-option = 0x1000000;
NOTE:
There must be exactly 6 spaces between HP and OPEN.
Instead of using the default round-robin algorithm, add the following lines in addition to the previous
lines for systems with a large amount of sequential I/O activity:
device-type-mpxio-options-list=
"device-type=HP
logical-block-options="load-balance=logical-block", "region-size=18";
NOTE:
There must be exactly 6 spaces between HP and OPEN.
For further information see document IDs 76504 and 76505 at http://sunsolve.sun.com.
For Solaris 8/9, perform a reconfiguration reboot of the host to implement changes to the config-
uration file. For Solaris 10, use the stmsboot command which will perform the modifications
and then initiate a reboot.
For Solaris 8/9, after you have rebooted and the LDEV has been defined as a LUN to the host,
use the cfgadm command to configure the controller instances for SAN connectivity. The controller
instance (c#) may differ between systems. Replace the WWPN in the example below with the
WWPNs for your array ports.
Example
# cfgadm -al
Ap_Id
Type Receptacle Occupant Condition
c3 fc-fabric connected configured unknown
c3::50060e8003285301 disk connected configured unknown
c4 fc-fabric connected configured unknown
c4::50060e8003285311 disk connected configured unknown
# cfgadm -c configure c3::50060e8003285301
# cfgadm -c configure c4::50060e8003285311
16
Installing and configuring Sun Solaris for the XP disk array
OPEN", "load-balance-options=logical-block-options";