Browse online or download pdf Configuration Manual for Switch HP XP20000/XP24000. HP XP20000/XP24000 40 pages. Hp storageworks xp disk array configuration guide: vmware (a5951-96106, september 2010)
Also for HP XP20000/XP24000: Release Note (13 pages), Integration Manual (29 pages), Release Note (4 pages), Administrator's Manual (50 pages), Configuration Manual (42 pages), Configuration Manual (40 pages), Configuration Manual (36 pages), Configuration Manual (36 pages), Configuration Manual (30 pages), Configuration Manual (36 pages), Release Note (5 pages), Configuration Manual (46 pages), Configuration Manual (46 pages), Reference Manual (46 pages), Configuration Manual (40 pages), Configuration Manual (44 pages), Configuration Manual (38 pages), Configuration Manual (34 pages), Configuration Manual (30 pages), Configuration Manual (30 pages)

HP XP20000/XP24000 Configuration Manual
2.
Select p to display the present partitions.
3.
Select n to make a new partition. You can make up to four primary partitions or you can make
one extended partition. The extended partition can be divided into a maximum of 11 logical
partitions, which can be assigned partition numbers from 5 to 15.
4.
Select w to write the partition information to disk and complete the fdisk command.
5.
Other commands that you might want to use include:
d to remove partitions
q to stop a change
6.
Repeat the above steps for each device.

Creating the file systems

The supported file system for Linux is ext2.

Creating file systems with ext2

1.
Enter mkfs
Example
# mkfs
2.
Repeat step 1 for each device on the disk array.
18
Installing and configuring Linux for the XP disk array
t ext2 /dev/device_name.
t ext2 /dev/sdd