Also for HP XP20000/XP24000: Release Note (13 pages), Integration Manual (29 pages), Release Note (4 pages), Administrator's Manual (50 pages), Configuration Manual (42 pages), Configuration Manual (40 pages), Configuration Manual (40 pages), Configuration Manual (36 pages), Configuration Manual (36 pages), Configuration Manual (30 pages), Configuration Manual (36 pages), Release Note (5 pages), Configuration Manual (46 pages), Reference Manual (46 pages), Configuration Manual (40 pages), Configuration Manual (44 pages), Configuration Manual (38 pages), Configuration Manual (34 pages), Configuration Manual (30 pages), Configuration Manual (30 pages)

HP XP20000/XP24000 Configuration Manual
AMCC/JNI 2 Gbit FCAs
Use JNIC146x driver (version 5.3.1.1).
Edit the FCA driver settings in the /kernel/drv/jnic146x.conf file.
For a SAN environment:
FcLoopEnabled
FcFabricEnabled = 1;
For a direct connect:
FcLoopEnabled
FcFabricEnabled = 0;
To enable failover for VxVM Dynamic Multi Pathing (DMP):
FailoverDelay = 30;
For SAN persistent binding:
automap = 0;
jnic146x0-target20_hba
jnic146x0-target20_wwpn
jnic146x1-target30_hba
jnic146x1-target30_wwpn
(Replace the WWPNs above with the WWPNs for your array ports.)
Make sure the jnic146x entry below is present at the bottom of the /kernel/drv/sd.conf file:
name="sd" parent="jnic146x" target=0;
Perform a reconfiguration reboot so the host can implement the changes you made in the config-
uration files.
After configuring LUNs as explained in
date_drv command to request that the jnic146x driver instances perform LUN rediscovery:
/opt/JNIC146x/jnic146x_update_drv -r -a

Verifying the FCA configuration

After installing the FCAs, verify recognition of the FCAs and drivers as follows:
1.
Log into the system as root. Verify that all devices are powered on and properly connected to
the system.
2.
Use the prtdiag command (SPARC only) to verify that the FCA is installed properly. Use the
prtconf command and/or browse the /var/adm/messages file to check whether the FCA
driver has attached. Look for the WWN/WWPN of the FCA in the /var/adm/messages file
or use an FCA-specific tool or command.

Clustering and fabric zoning

If you plan to use clustering, install and configure the clustering software on the servers.
= 0;
= 1;
= "jnic146x0";
= "50060e8003285301";
= "jnic146x1";
= "50060e8003285311";
"Defining the
paths" on page 10, use the jnic146x_up-
XP Disk Array Configuration Guide: Solaris