HP XP20000/XP24000 Configuration Manual - Page 34

Browse online or download pdf Configuration Manual for Switch HP XP20000/XP24000. HP XP20000/XP24000 44 pages. Hp storageworks xp disk array configuration guide: vmware (a5951-96106, september 2010)
Also for HP XP20000/XP24000: Release Note (13 pages), Integration Manual (29 pages), Release Note (4 pages), Administrator's Manual (50 pages), Configuration Manual (42 pages), Configuration Manual (40 pages), Configuration Manual (40 pages), Configuration Manual (36 pages), Configuration Manual (36 pages), Configuration Manual (30 pages), Configuration Manual (36 pages), Release Note (5 pages), Configuration Manual (46 pages), Configuration Manual (46 pages), Reference Manual (46 pages), Configuration Manual (40 pages), Configuration Manual (38 pages), Configuration Manual (34 pages), Configuration Manual (30 pages), Configuration Manual (30 pages)

HP XP20000/XP24000 Configuration Manual
Emulation
Category
(Note 1)
(Note 2)
LUSE
OPEN-3*n
SCSI disk
OPEN-8*n
SCSI disk
OPEN-9*n
SCSI disk
OPEN-E*n
SCSI disk
OPEN-L*n
SCSI disk
CVS
OPEN-3 CVS
SCSI disk
OPEN-8 CVS
SCSI disk
OPEN-9 CVS
SCSI disk
OPEN-E CVS
SCSI disk
OPEN-V
SCSI disk
CVS LUSE
OPEN-3*n CVS
SCSI disk
OPEN-8*n CVS
SCSI disk
OPEN-9*n CVS
SCSI disk
OPEN-E*n CVS
SCSI disk
OPEN-V*n
SCSI disk

General notes:

*Capacity = (512 x number of blocks) ÷ 1024
The value n is the number of volumes combined together. For example, with 8 combined volumes:
OPEN-V*8.
Note 1:
The availability of an emulation depends on the disk array.
Note 2:
The devices are defined to the host as SCSI disk devices, even though the interface is Fibre Channel.
Note 3:
The command device (used for RAID Manager) is distinguished by -CM on the product name (for
example, OPEN-3-CM, OPEN-3-CVS-CM).
34
Disk array supported emulations
Product name
Blocks
(Note 3)
(512 bytes)
OPEN-3*n
4806720*n
OPEN-8*n
14351040*n
OPEN-9*n
14423040*n
OPEN-E*n
28452960*n
OPEN-L*n
71192160*n
OPEN-3-CVS
Note 5
OPEN-8-CVS
Note 5
OPEN-9-CVS
Note 5
OPEN-E-CVS
Note 5
OPEN-V
Note 5
OPEN-3*n-CVS
Note 5
OPEN-8*n-CVS
Note 5
OPEN-9*n-CVS
Note 5
OPEN-E*n-CVS
Note 5
OPEN-V*n
Note 5
Sector size
# of
(bytes)
cylinders
512
3338*n
512
9966*n
512
10016*n
512
19759*n
512
49439*n
512
Note 6
512
Note 6
512
Note 6
512
Note 6
512
Note 6
512
Note 6
512
Note 6
512
Note 6
512
Note 6
512
Note 6
2
Heads
Sectors
Capacity
per track
(Note 4)
15
96
15
96
15
96
15
96
13893*n
15
96
34761*n
15
96
15
96
15
96
15
96
15
128
15
96
15
96
15
96
15
96
15
128
MB*
2347*n
7007*n
7042*n
Note 7
Note 7
Note 7
Note 7
Note 7
Note 7
Note 7
Note 7
Note 7
Note 7