Panasonic PT-F200NTEA/PT-FW100NTEA User Manual - Page 37

Browse online or download pdf User Manual for Projector Panasonic PT-F200NTEA/PT-FW100NTEA. Panasonic PT-F200NTEA/PT-FW100NTEA 49 pages. Network function edition

Using WebBrowser

Monitor information window

This page indicates the projector status.
To access this page from other pages, click [Status] at the left of the window.
Monitored information
On this window, click the [Status information] tab.
The monitor information is refreshed at fixed intervals, but the current exact information can be checked by clicking [View]
[Reload Page].
If [SELF TEST Error(Detail)] appears on the
monitored information window, click it to view the error
details.
If [FAILED] appears
Item
MAIN CPU BUS
FAN
INPUT/OUTPUT AIR TEMP.
LAMP REMAIN TIME
LAMP STATUS
ARF UNIT
INPUT AIR TEMP.SENSOR
OUTPUT AIR TEMP.SENSOR
BATTERY
(cont.)
Description
There is a problem with a microcontroller circuit. Contact your dealer.
There is a problem with the fan or fan drive circuit. Contact your dealer.
Excessive temperature by the air intake or around the lamp area.
The following may be causing the problem.
• The ambient temperature is too hot; the projector may be near a heater
• The exhaust vent is obstructed
The lamp has been used for longer than its rated useful life, and it is time to replace it.
The lamp could not be lit.
Allow the bulb of the light source to cool, and then turn on the projector.
ARF UNIT is not installed or remaining filter level is low.
See instruction manual of the projector for detail.
There is a problem with the air intake temperature sensor. Contact your dealer.
There is a problem with the exhaust temperature sensor. Contact your dealer.
The battery must be replaced. Contact your dealer.
37
Network information
On this window, click the [Network status] tab.