X. TS400: ELECTRICAL MOTOR SPECIFICATION
Horse Power
Voltage
Amps
Cycle
Phase
Class
No Load Blade Shaft
Black
Green
WARNING!
To avoid permanent motor damage, always use
the correct extension cord.
RECOMMENDATIONS:
TS400
2 HP
115V~120V
15 amps
60 Hz
1
F
3300 rpm
Circuit
Switch
Breaker
Black
White
Water
Pump
• 13 • diamondvantage.com
It is recommended that a minimum 15 amp circuit be used
while operating this saw. This will prevent possible power
interruption or loss.
Always plug saw as close as possible to the power source
while operating. This will allow you to receive optimum
electricity.
TS400
Black
Black
White
Green
Wire
Gauge
No. 12
No. 10
No. 8
Motor
Black
White
Green
Green
LENGTH OF CORD
2 HP
115V~120V
25'
50'
75'