Alpha Communications VMH25WH Series Installation And Use Instructions Manual - Page 6

Browse online or download pdf Installation And Use Instructions Manual for Intercom System Alpha Communications VMH25WH Series. Alpha Communications VMH25WH Series 8 pages.

TYPICAL WIRING DIAGRAM FOR SINGLE ENTRANCE SYSTEM
WITH S.T.R.™ STYLE CAMERA AND MULTIPLE VIDEO RISERS
USING A SINGLE VDU-4 VIDEO DISTRIBUTOR UNIT
Notes:
1. All wiring is #22AWG unless shown otherwise.
2. When using a PINHOLE type camera, instead of the standard S.T.R.™ type camera, see the special camera
installation and connection instructions found on page 8, and do not power as shown above.
3. DO NOT CONNECT MORE THAN 10 MONITORS PER VIDEO RISER/LINE.
4. Observe all local and national electrical and building codes.
5. All terminals connections shown may not be in the order that they appear on the equipment.
AND 1-4 MONITORS
6
Note: For more
information on
the VDU-4, or
when connecting
multiple VDU-4
units together, for
more than 4 video
risers, see wiring
diagram #AWD061