Alpha Communications TekTone NC377 Installation & Operating Instructions Manual - Page 3

Browse online or download pdf Installation & Operating Instructions Manual for Adapter Alpha Communications TekTone NC377. Alpha Communications TekTone NC377 12 pages. Paging interface adapter

Chapter 2—Installation
Mounting & Cable Routing
Verify that power to the unit is disconnected before proceeding.
Please follow these steps. (Note: The terms zone and input are
used interchangeably in this manual and on the programming
screens.)
1. Remove the four Phillips-head screws located on top of the
NC377 Paging Interface Adapter.
2. Remove the top cover and set aside.
3. Using the hardware supplied, mount the NC377.
4. If the cable you are using has bundled wires, strip the outside
covering back 24 inches.
5. Loop the cable in a U shape and attach it to the NC377 using
the tie-wraps provided. (See Figure 2.)
6. Route the wires through the access holes on the back of the
unit.
7. With the front of the unit facing you, inputs 1–32 are on the
left and 33–64 are on the right. (See Figure 3.)
8. Route your cables so that they do not cross over the board
inside the NC377 Paging Interface Adapter.
Nurse Call Wire Connections
Referring to Figure 3, route and connect the individual lamp
select wires.
1. If all the inputs have a common ground, it is not necessary
to attach individual grounds to each input on the terminal
block. Simply attach the common ground to terminal number
2(–) and place an internal jumper on the other terminals
(negative terminals 2, 4, 6, 8, etc.).
2. Attach the first Lamp Select Wire (positive wire) to terminal
1(+).
3. Continue until all inputs are connected.
4. Replace the top cover and the four Phillips-head screws.

Power Up Sequence

Referring to Figure 4 and the following steps, connect all the
required cables.
1. Connect the power lead to the rear of the unit, and apply
power.
2. On the front panel, turn on the power switch. The green
power LED indicator will light.
4. Connect the RS232 serial cable from the NC377 Paging
Interface Adapter to the paging transmitter's input. (The
RS232 cable is provided with the paging transmitter. To build
a longer cable or a new cable, see the paging transmitter's
manual.)
5. Apply power to the paging transmitter.
6. The NC377 is now ready to be programmed.
Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.
Chapter 3—Programming Plan
This section outlines the overall programming plan. Refer to
Chapter 4—Programming for step-by-step programming
instructions. (Note: The terms zone and input are used
interchangeably in this manual and on the programming screens.)
Before use, perform Global Settings Programming on each
NC377. The NC377 Paging Interface Adapter may be ordered
with either 32 or 64 points. Configure each NC377 as either a
master or a slave. There must always be one master, but there
may be up to eight slaves.
1. Each NC377 Paging Interface Adapter will be connected
separately for the global settings programming. After pro-
gramming, they will be connected together for system
operation.
2. The gray crossover cable is used to connect the PC/laptop
to the NC377 for programming.
3. If multiple NC377s will be connected together, program the
slaves first. Only these four fields are programmed on the
slave units:
• Host System (TekTone
• Unit ID: Slave
• Slave #
• Total Number of Contacts (32 or 64)
4. Label each NC377 with its Slave # or as the Master so it can
be identified in the future.
5. Program the master NC377 after all slaves have been pro-
grammed. Contact input programming is performed only on
the master NC377.
®
6. Select TekTone
as the host system on both masters and
slaves.
7. Each NC377 has a maximum capacity of 64 inputs, with a total
576 when all 8 slaves are connected. The contact numbers
run in sequence:
Master
1–64
Slave1
65–128
Slave2
129–192
Slave3
193–256
Slave4
257–320
Slave5
321–384
Slave6
385–448
Slave7
449–512
Slave8
513–576
If an NC377 has fewer than 64 inputs connected, program
only the inputs that are connected. The contacts can be
connected in any order, i.e. 1–16 or 32–48.
After global settings programming is complete, perform
Contact Input Programming on the master NC377 to program
the inputs being used.
IL871 NC377 Paging Interface Adapter Manual • Page 3
®
)