when the battery voltage is higher than UWRV, the controller will exit the intelligent
power mode.
NOTE:The load is ON when the controller power on 1seconds. After 1
seconds it will restore to set working mode.
NOTE: In the mode of Light ON/OFF and Light ON/Timer, the Load is
turned on after 1Min. delay.
7. Accessories(optional) and Software
Software
(1)Solar station Monitor
 Download software
www.epsolarpv.com/en/index.php/Technical/download——PC Software for the Solar
Charge Controller
(2)Mobile APP software setting(Only android phones are supported)
www.epsolarpv.com/en/index.php/Technical/download——Andriod
Li-Battery Solar Charge Controller
※Specific instructions refer to the list of accessories and software.
8. Protection
 PV Short Circuit
 If the PV array short circuit, the controller will stop charging, clear it to resume normal
operation.
 PV Reverse Polarity
 Fully protection against PV reverse polarity, correct the wire connection to resume
normal operation.
 Battery Reverse Polarity
 Fully protection against battery reverse polarity, correct the wire connection to
resume normal operation.
 Battery Over Voltage
 When the battery voltage reaches to the set point of Over Voltage Disconnect Voltage,
the controller will stop charging the battery to protect the battery from being over
charged to break down.
 Battery Over Discharge
When the battery voltage reaches to the set point of Low Voltage Disconnect Voltage,
the controller will stop discharging the battery to protect the battery from being over
discharged to break down.
 Battery Overheating
 The controller detect the environment temperature through the external temperature
sensor. If the environment temperature exceeds 65 º C, the controller will
automatically start the overheating protection to stop working, and recover below 50
º C.
 Libattery low temperature★
 The controller detect the environment temperature through the external temperature
sensor. If the temperature sensor is less than the low temperature value, the
controller will automatically stop charging or discharge and recover higher than the
low temperature value.
 Load Short Circuit
 Load will be switched off when load short circuit (≥4 times rated current) happens.
Controller will automatically attempt to reconnect load for 5 times. If short circuit
protection still exist after controller's 5 times attempts, user have to clear short
circuit ,then restart the controller or wait for one night-day cycle (night time>3 hours).
 Controller Overheating
 If the temperature of the controller exceeds 85 º C, the controller will automatically
start the overheating protection, and recover below 75 º C.
 High Voltage Transients
 The controller is protected against small high voltage transients. In lightning prone
areas, additional external suppression is recommended.
★Warning: If selecting a lithium battery, it must be set low temperature
value(LTV) according to the charging/ discharging temperature of lithium
battery; otherwise, the lithium battery will be damaged.
9. Troubleshooting
Faults
Possible reasons
LED Charging
indicator turn off
during daytime
PV
when sunshine falls
array disconnection
on PV modules
properly
The lithium battery
protection plate is
disconnected at low
pressure and the
No LED indicator
photocell is not
connected;
Battery voltage maybe
less than 9V
Battery LED
indicator green fast
Battery over voltage
Flashing
Battery LED
Battery
indicator red
over discharged
Battery LED
Battery Overheating
BEIJING EPSOLAR TECHNOLOGY CO., LTD.
APP
Troubleshooting
Confirm that PV and battery wire
connections are correct and tight
Measure battery voltage with the
multi-meter. Min.9V can start up the
controller
Check if battery voltage is higher
than OVD, and disconnect the PV
When the battery voltage is restored
to or above LVR point (low voltage
reconnect voltage), the load will
recover
The controller will automatically turn
3
Tel:+86-10-82894112 / 82894962 Website:www.epsolarpv.com/www.epever.com
indicator red
flashing
Charging(green)
and battery
indicator
(orange)flashing
simultaneously
Powering on
normally, the load is
off
The dimming
function is invalid
for
the
10. Technical Specifications
Item
Nominal system voltage
Battery input voltage range
Max. PV open circuit
voltage
Rated charge current
Max. output current
Max. output power
Output voltage range
Load open circuit voltage
Max. output efficiency
Output current control
accuracy
Battery Type
Equalization Voltage
Boost Voltage
Float Voltage
Low Voltage
Reconnect Voltage
Low Voltage Disconnect
Voltage
Boost Voltage
Low Voltage
Reconnect Voltage
Low Voltage Disconnect
Voltage
Self-consumption
Charge Circuit Voltage
Drop
Temperature compensation
coefficient
Working environment
temperature
Enclosure
Grounding
Overall dimension
Mounting dimension
Mounting hole size
Power cable
Net weight
★When the battery type is lithium battery, the controller doesn't support self-activation.
▼Battery Voltage Control Parameters (below parameters are in 12V system at 25 º C,
please double the values in 24V system)
DO NOT connect the PV array when change the lithium battery type via the
phone APP or PC software.
11. Disclaimer
This warranty does not apply under the following conditions:
 Damage from improper use or use in an unsuitable environment.
 PV or load current, voltage or power exceeding the rated value of controller.
 The controller is working temperature exceed the limit working environment
temperature.
 User disassembly or attempted repair the controller without permission.
 The controller is damaged due to natural elements such as lighting.
 The controller is damaged during transportation and shipment.
the system off. But while the
temperature decline to be below 50
º C, the controller will resume.
please try to decline the
environment's temperature, or the
Controller overheating
power of PV or the power of the load
Check whether the battery voltage
match with the controller's working
System voltage error
voltage, If not please change to a
suitable battery or reset the working
voltage
①The connecting
①Check the connecting cable.
wires are error or
②Check the load's mode and
virtually connected
parameters.
②Load mode is not
③The voltage of LED light is not
appropriate.
within the output voltage range of
③This controller does
controller.
not match with the LED
④Check the connecting cables and
light.
LED light.
④Output short circuit.
The controller does not
①Replace the LED light
match with the LED
②Reduce system rated voltage
light source. This
grade and replace the product
product is a step-up
model
voltage control, If input
For example 24V system change to
voltage is lower than
12V system, and replace the
the rated voltage, it is
corresponding controller
not working.
LS102460BPL
12/24VDC Auto
10A
2.0A
30W/12V;60W/24V
Max. battery voltage+2V~60V
Lead-acid battery: Sealed(default)/Gel/Flooded/User
Lithium battery
:LiFePO4/Li-NiCoMn/User
Sealed:14.6V; Flooded:14.8V;User:9-17V
Sealed:14.4V;Gel:14.2V;Flooded:14.6V;User:9-17V
Sealed/Gel/Flooded:13.8V;User:9-17V
Sealed/Gel/Flooded:12.6V;User:9-17V
Sealed/Gel/Flooded:11.1V;User:9-17V
LiFePO4(4s):14.5V/Li-NiCoMn(3s):12.5V/User:9-17V
LiFePO4(4s):12.8V/Li-NiCoMn(3s):10.5V/User:9-17V
LiFePO4(4s):11.1V/Li-NiCoMn(3s):9.3V/User:9-17V
≤11mA/12V;≤9mA/24V
-3mV/℃/2V
-35℃~+55℃
Common Positive
107x73x20mm
100mm
Φ4
PV/BAT: 14AWG(2.5mm
LOAD: 18AWG(1.0mm
0.28kg
Any changes without prior notice! Version number:V3.0
4
LS2024100BPL
9V~32V
50V
20A
3.3A
50W/12V;100W/24V
60V
96.7%
≤30mA
≤0.3V
IP67
108.5x102x25.6mm
100.5x80mm
Φ5
2
2
)
PV/BAT:12AWG(4.0mm
)
2
2
)
LOAD: 18AWG(1.0mm
)
0.46kg