Alpha Motors WSER50 Series Quick Start Manual

Browse online or download pdf Quick Start Manual for Engine Alpha Motors WSER50 Series. Alpha Motors WSER50 Series 2 pages.

WSER Universal Motors
Single-Control Switch(be compatible with 5-core wires ER tubular motor)
B If you want to use the motor with Single-Control switch, please connect motor and switch as per below indication firstly.
Then use an assigned remote to do following steps:
---Short press emitter's UP&DOWN button simultaneously and release.
---Short press emitter's STOP button 7 times;
---Short press DOWN button one time and release, the motor jiggles.
Now you can use the Single-Control switch to control the tubular motor properly. The tubular motor will run Up - Stop- Down - Stop-Up-Stop cycle when
the switch is pressed each time.
AC Power
up
120V
stop
down
Announcement
1. The RE101 remote has been used as an example here in diagrams. All Alpha remotes are compatible
with these motors.
2. Strong local RF levels from other equipment may affect some setup functions. If a step fails, simply
repeat the process.
3. Be careful not to speed through the setup process until you are 100% sure of what you are doing.
4. These motors and accessories are not toys, do not allow children to play with them.
5. Ambient operating temperature is: -10 C - +55 C
6. All Alpha products may be subject to change without notice.
Handy Tips
1. If this motor is used on an awning and works with the Alpha RS001wind-light
sensor or RS005 motion sensor, there is constant radio communication between the
motor and sensor. If the motor doesn't receive radio communication from the sensor
for 35 minutes after opening, the motor will automatically close the awning as a
protective measure. This indicates that there is either a problem that needs investigat
-ion, or in the case of the motion sensor that the batteries might need changing.
2. Always roll the blind down and up before setting the top limit. Failure to do so
may result in a change of limit position due to a change in blind tension. Simply
setting the bottom limit first will prevent this happening.
3. When pressing up and down simultaniously during setup, be as precise as
possible. Ideally it should sound like one button click when both are pressed.
4. If you catch yourself making an error during a setup process, stop and allow 10
seconds for the motor to time out, then try again.
5. Do not hold any buttons down during setup process unless specifically told to do
so. A half second press should be plenty and allow 1 second between presses.
6. If you are using a multi-channel remote, make certain that it is on the correct
channel before you assign it to a motor. This is a common mistake.
ER Motors Instruction
Page 4.
antenna
neutral wire (white)
ground wire(green)
live wire (black)
purple
blue
WSER Universal Motors
Technical Specifi cations
1
Power AC 120v/60Hz
Protection Index: IP 44
Loaded Power 400w
Wire Connections
2
AC Power
up
120V
stop
down
Assigning a remote to a motor (You have 10 seconds to complete the task)
3
Method A.
Only works for the fi rst
remote assigned to the motor.
1
AC Power
1
Turn power on, the motor
Press the UP and DOWN buttons
will vibrate
simultaneously, then release.
Method B.
Can be used at any time.
1
1
Press the red button on the motor
Press the UP and DOWN buttons
for 1 second
simultaneously, then release.
Method A. can only be used again if you cut and restore power to the motor 3 times. You must allow 5 seconds before restoring
power each time and you must allow the motor to vibrate properly each time. After the third cycle, you may assign the remote.
Assigning an extra remote (or channel) to a motor via the original remote
4
1
8
1
Original
Original
Press the UP and DOWN
Press the STOP button
buttons simultaneously,
8 times, the motor will
then release.
vibrate.
Deleting a remote (or channel) from a motor (You have 10 seconds to complete the task)
5
Method A.
This will delete the individual remote (or channel) you are currently using
1
7
Press the UP and DOWN
Press the STOP button 7 times.
buttons simultaneously, then
release.
04
ER Motors Instruction
Page 1.
Up to 15 remotes (or channels) may be assigned to each motor
Thermal protection will engage after 4 minutes of continuous running
antenna
neutral wire (white)
ground wire(green)
live wire (black)
1
Press the STOP button once,
You can now use the remote
the motor will vibrate.
to control the motor.
1
1
Press the STOP button once, the
You can now use the remote to
motor will vibrate.
control the motor.
1
1
1
NEW
NEW
Press the UP and DOWN
Press the STOP button
buttons simultaneously,
once, the motor will
then release.
vibrate.
1
1
Press the UP button once, the
This remote (or channel) has now
motor will vibrate
been deleted from the motor.
06.04.SMS-ERJB-8479-V2
You can now use the new
remote to control the motor.
01