Alpha Outback Energy Radian Series Quick Start Manual - Page 2
Browse online or download pdf Quick Start Manual for Inverter Alpha Outback Energy Radian Series. Alpha Outback Energy Radian Series 4 pages.
Installation
1
Ensure the mounting surface is strong enough to handle 3 times the total weight of all the components. Add plywood or other
reinforcing material as necessary to strengthen the surface.
2
Attach the wall bracket. Center the mounting holes on the wall studs. Use all 6 mounting screws to secure the bracket.
3
Lift the inverter so that the inverter bracket is above the wall bracket.
4
Lower the inverter so that the inverter bracket slips into the wall bracket.
5
If GSLC is not used: Secure the inverter to the surface using a minimum of 1 wall screw (or appropriate hardware).
If GSLC is used: Unscrew the inverter bottom screws approximately (0.6 cm (¼") to 0.5 cm (3/16").
6
7
Align the GSLC along the bottom of the inverter. Slide the bottom screws into the keyhole slots.
8
Mark the spots for the GSLC mounting feet. (If necessary, remove the GSLC to install wall anchors.) Install screws to secure the feet.
9
Follow the appropriate instructions for installing other components. Different mounting locations are available.
1.3 cm (0.5")
1.3 cm (0.5")
40.6 cm (16.0")
34.8 cm (13.7")
ON/OFF
+ -
INV
RELAY
12V
Switch
Remote
Battery
AUX
AUX
INV
Temp
When
stacking
multiple
inverters:
114.3
For GSLC door
cm
clearance, space
(45.0")
systems 3.2 cm
N
N
N
L1 L2
L1 L2
L1 L2
E
E
E
OUT
GEN
GRID
U
U
U
(0.9") apart.
The Radian allows two locations
for the MATE3 mounting bracket
(FW-MB3).
The Radian has one
mounting location for the
HUB product. The GSLC
also has one location.
900-0159-01-00 REV C.vsd\Page 2\2015-09-30
22 cm
(8.75")
Wall Stud
Wall Board
Plywood
(Optional)
Inverter
Bracket
3
Wall
Bracket
71.1 cm
74.0 cm
(28.0")
(29.1")
4
Right Side:
Left Side:
The FLEXmax charge
controller is mounted
with the FW-CCB bracket.
The FW-CCB2 allows two
controllers side by side (using
the forward holes to allow for
conduit.)
The Radian has two sets of
9
bracket positions. The GSLC
has one set.
NOTE: The FLEXmax
Extreme charge controller
attaches directly to the wall,
not the Radian system.
It does not use
OutBack brackets.
Wall
40.6 cm (16.0")
Stud
1
Plywood (Optional)
10.4 cm
2
(4.1")
Wall Bracket
Wall Board
15.2 cm
20.3 cm
(6.0")
(8.0")
AC Wire Sizes and Torque Values
Wire Size
mm
AWG
2
2.5 to 6
#14 to #10
6
10
#8
5
16 to 25
#6 to #4
35
#3
35
#2
50
#1
Bottom
Bottom
70
1/0
Screws
Screws
Keyhole Slots
OutBack recommends that conductors be
2
7
16 mm
copper, or larger, rated to 75°C
(minimum) unless local code requires otherwise.
Minimum DC Cable based on
the DC Circuit Breaker
Circuit
Cable Size
Breaker
60
#6 AWG (16 mm
35.6 cm
80
#4 AWG (25 mm
(14.0")
125
1/0 (70 mm
175
2/0 (70 mm
250
4/0 (120 mm
31.8 cm
8
(12.5")
Circuit Breaker
Stud
M8
¼ - 20
5/16 - 18
3/8 - 16
Positive Battery Cable Connections
4
DC Disconnect
Bolt 3/8"
Stud
Battery
Positive
Positive
Flat
FM80
(+) Lug
Washer
Positive (+)
DC
Terminal
Positive
(+) Plate
19
Washer
Flat
Lock
FN-DC
Washer
Washer
Positive (+)
Washer
Sense
Nut
Nut
Terminal
GSLC175-PV-230
GSLC175PV1-230
Wall
Stud
GS7048E
12.7 cm
MATE3
(5.0")
9
ON/OFF
INV
RELAY
+ -
Switch
Remote
Battery
AUX
12V
AUX
INV
Temp
10
9
Torque
Nm
In-lb
1
2.3
20
2.8
25
L N
L N
L N
OUT
GEN
GRID
4.0
35
4.0
35
4.5
40
HUB
5.6
50
10.3
5.6
50
9
3
7
17
15
Torque
11
Nm
In-lb
5
2
)
4.0
35
6
2
)
4.0
35
2
)
5.6
50
2
)
25.4
225
2
)
25.4
225
GSLC175-PV-230
Torque Requirements
Torque
Torque
DC Plates
Nm
In-lb
Nm
In-lb
2.3
20
Upper holes (+)
6.8
60
60
4.0
35
Lower holes (+)
5.6
50
5.6
50
Shunt Bolts (–)
6.8
60
and GS-SBUS
25.4
225
Negative Battery Cable
CAUTION:
!
Connections
Equipment Damage
Battery
When connecting cables
from the Radian inverter
(+) Lug
Flat
to the battery terminals,
Washer
DC
Negative (-)
make sure to observe
Plate
the proper polarity.
(GS-SBUS)
Flat
Connecting the cables
22
incorrectly can damage
Lock
or destroy the equipment
Shunt
and void the product
20
warranty.
RADIAN Series
1
AC Terminals - Inverter
2
DC Terminals - Inverter
3
AC Circuit Breakers
4
DC Circuit Breakers
5
GFDI
6
PV Circuit Breakers
7
Mechanical Interlock (Bypass)
8
Charge Controller Terminals
9
Communication Ports
10
Auxiliary Terminals
11
AC OUT Bus Bar
12
GRID IN Bus Bar
13
GEN IN Bus Bar
14
AC Neutral
15
Ground
16
DC Positive (+) Plate
(not used in GSLC175PV1-230)
17
PV Negative (–) Terminals
18
PV Positive (+) Bus Bars
19
DC Negative (–) Plate (GS-SBUS)
2
2
19
4
16
12
13
8
8
18
9
9
14
18
10
10
FM80 #1
FM80 #2
FN-DC
FN-DC LED Indicators
Color
Battery State of Charge
> 90% (blinks if charge parameters
Green
are met)
≥ 80%
Yellow
≥ 70%
Yellow
≥ 60%
Yellow
≥ 60% off, < 60% solid, < 50% blinks
Red
FN-DC wiring is displayed
on the Wiring page.
Bolt 3/8"
Wiring to AC terminals is
Battery
displayed on the Wiring page.
Lock
Negative
Washer
(–) Lug
1
L
N
L
N
L N
OUT
GEN
GRID