Verify that the voltage at the power inlet is between
100 — 240 V AC.
•
Verify that the power inlet cable is functional.
The powered device does not operate
•
Verify that the powered device is designed for PoE operation.
•
Verify that a standard Category 5/5e/6, straight-wired cable
with four pairs is used.
•
Verify that the input Ethernet cable is connected to the
DATA IN port.
•
Verify that the powered device is connected to the
DATA & POWER OUT port.
•
If an external power splitter is in use, verify that it works.
•
Verify that there is no short over on any of the twisted pair
cables or over the RJ45 connectors.
•
If possible reconnect the same powered device into a different
midspan.
The end device operates, but there is no data link
•
Verify that the port on the front panel is continuously lit.
•
Verify that a standard Category 5/5e/6, straight-wired cable
with four pairs is used.
•
Verify that the Ethernet cable length is less than
100 m (330 ft) from the Ethernet source to the load/remote
terminal.
•
If an external power splitter is in use, verify that it works.
•
If possible reconnect the same powered device into a different
midspan.