SolaStat-Eco Programming.

If the adjustable values from the factory are inappropriate for the installation (see included document
stating programmed values) then the unit needs to be programmed.The programming access
code is for distributor or installer use only, as using incorrect adjustable values can cause
inefficiencies in the system or cause damage to the system voiding the warranty. Once new values
are 'stored' they are permanently written into memory and will be retained when power is removed
SolaStat-Eco Panel Description.
F1 Light
F2 Light
1.
The small yellow letters / words under the buttons now apply.
2.
Enter the installer programming access code. Available from distributors.
3.
All 4 lights will flash 4 times indicating you are in programming mode.
4.
The 'PUMP' light will be flashing to indicate the adjustable value is the Pump ON / Pump
OFF value.
F
F
F
F
5.
Select one of the adjustable values by pressing the corresponding button e.g. to
programme 12C ON / 6C OFF press button 'F4' and the F4 light will be on for a second.
6.
Now the 'TOPOUT' light will be on to indicate the adjustable value is the 'TOPOUT'
temperature. Wait for the light to change from steady on to flashing.
F
F
F
F
7.
Select one of the adjustable values by pressing the corresponding button. (Selecting 'F1'
will disable the 'TOPOUT' function and the F1 light will be on for a second).
8.
Now the 'FROST' light will be on to indicate the adjustable value is the 'FROST'
temperature. Wait for the light to change from steady on to flashing.
F
F
F
F
9.
Select one of the adjustable values by pressing the corresponding button. (Selecting 'F1'
will disable the 'FROST' function and the F1 light will be on for a second).
10. All the values have now been entered and will automatically be stored in permanent
memory.The unit will also store the values and exit if no key is pressed for a minute while
in programming mode.
11. Fill out the 'System Adjustable Values' in the user guide. (Page 6.)
P
u
m
p
O
1
5
C
2
8
C
3
1
0
C
4
1
2
C
P
u
m
p
O
1
D
s i
a
b
e l
2
5
8
C
3
7
3
C
4
9
3
C
P
u
m
p
O
1
D
s i
a
b
e l
2
2
C
3
4
C
4
6
C
N
P
u
m
2
4
5
6
N
P
u
m
D
s i
6
7
9
N
P
u
m
D
s i
4
6
8
19.03-11
p
O
F
F
C
C
C
C
p
O
F
F
a
b
e l
0
C
5
C
5
C
p
O
F
F
a
b
e l
C
C
C
F3 Light
F4 Light