EPHESUS Arena 650 Installation Instructions Manual - Page 7

Browse online or download pdf Installation Instructions Manual for DJ Equipment EPHESUS Arena 650. EPHESUS Arena 650 16 pages. All field led luminaire

Step 2 – Label the Luminaires (If Required)
For outdoor applications where smaller groups of luminaires are installed on poles, it is not necessary to label the fixtures. If
you are installing fixtures on poles or other applications where labeling is not required, skip this step and proceed to step 3.
For indoor applications where many luminaires are installed in a row along a catwalk, the fixtures are typically labeled to
facilitate identifying each one at a glance from the catwalk.
1.
Label each fixture with Luminaire Number as indicated on schedules in the project Installation drawings.
2.
Labels shall be white background with black lettering. Text shall be at least 1/4" (6mm) tall.
3.
Affix the label to the mounting bracket in a prominent location, avoiding manufacturer labels.
Step 3 – Make Electrical Connections
Never connect the luminaire to an electrical system that is not grounded. Installing a luminaire in an ungrounded
electrical system could allow the metal housing to become energized in the event of an electrical short, resulting in
the risk of electrical shock for anyone who comes into contact with the fixture. FAILURE TO FOLLOW THIS WARNING
MAY LEAD TO DEATH, SEVERE INJURY, OR PROPERTY DAMAGE.
Figure 5. Luminaire Label
WARNING
Installation Instructions - All Field LED Luminaire
EATON
MN507001EN
All Field Installation Manual rev 20170324
7