Axis Electronics NANO-600G10 User Manual - Page 16

Browse online or download pdf User Manual for Scales Axis Electronics NANO-600G10. Axis Electronics NANO-600G10 17 pages. Electronic weighing scale

Axis Electronics NANO-600G10 User Manual

8 TROUBLESHOOTING

SYMPTOM
Scale will not
power on
Battery does not
give enough
backup
Weight reading
on scale does not
stabilize
Scale does not
show weight
accurately
External
calibration is not
stored after
switch on / off
the machine
Weight not enough
for
setting
LOW
Machine
message and turns
off
POSSIBLE CAUSE
If running on batteries, the
battery may have fully
discharged.
AC Power cord not connected.
The battery is defective. The
battery may have past its useful
life. (Generally 6months – 1 year)
External Rubbing / Friction A
scale
cannot
accurately if an object is
rubbing or pressing against
the scale platform. Mobile
interference,
wind could be other possible
reasons
Improper calibration
This happens when the Internal
to External calibration variance
larger than 2%. The cause could
be that the user is not using
correct weight.
NANO Series Precision Balance
the
selected
Battery.
displays
measure
Vibration
or
16
Keep
weight
more weight on pan for
correct results.
Battery is low. Connect
scale to power so that
the
battery
charged.
REMEDY
Connect scale to power
source.
Recharge battery
Change the battery.
Move the scale away from
mobile signal, breeze or
vibration areas.
Calibrate the scale again
to and check for the
problem again.
Use correct weights to
calibrate. If the problem
persists, calibrate the
scale using internal
calibration routine.
or
Add
can
be