Olympus DS-2000 Online Instructions Manual - Page 44

Browse online or download pdf Online Instructions Manual for Voice Recorder Olympus DS-2000. Olympus DS-2000 48 pages. Dss player for mac os 9 instructions (english)
Also for Olympus DS-2000: Instructions Manual (44 pages), Instructions Manual (36 pages)

Olympus DS-2000 Online Instructions Manual

Troubleshooting

Symptom
Probable cause
Nothing
The batteries are not loaded properly.
appears on
The batteries are dead.
the display
The POWER/LOCK switch is set to OFF.
If none of these suggestions works
Won't start
The recorder is in HOLD mode.
The SmartMedia card is not formatted.
The batteries are dead.
Unable to
The SmartMedia card has a write-protect seal
record
attached to it.
The SmartMedia card is unformatted.
The SmartMedia card does not have enough memory.
The maximum number of files has been reached.
No playback
The earphone is connected.
tone heard
The VOLUME control is set to 0.
Unable to
The file is locked.
erase
The SmartMedia card has a write-protect seal
attached to it.
Noise heard
The recorder was shaken during recording.
during
The recorder was placed near a cell phone or
playback
fluorescent lamp while recording or during playback.
Recording
The microphone sensitivity is too low.
level too low
The maximum number of index marks (16) has been
Unable to set
reached.
index marks
The SmartMedia card has a write-protect seal
attached to it.
The file is locked.
Won't work
A non-standard AC adapter is being used.
with AC
adapter
Unable to
The POWER/LOCK switch is set to ON.
eject the
SmartMedia
44
card
Action
Verify polarity is correct.
Replace with new batteries.
Set the POWER/LOCK switch to
ON.
Reset the recorder ( P.40).
Release the recorder from HOLD
( P.40).
Format the SmartMedia card
( P.38).
Replace with new batteries.
Remove the seal.
Format the SmartMedia card.
Erase unnecessary files or insert
another SmartMedia card.
Check another folder.
Disconnect the earphone jack.
Adjust the VOLUME control.
Unlock the file ( P.30, 31).
Remove the seal.
Move the recorder.
Set the microphone sensitivity to
CONF mode and try again.
Erase unnecessary index marks
( P.29).
Remove the seal.
Unlock the file ( P.30, 31).
Use the Olympus A321 (for US,
Canada) or A322 (for Europe
except U.K) AC adapter
(Oprional).
Set the POWER/LOCK switch to
OFF.