Olympus U-FH Instructions Manual - Page 24
Browse online or download pdf Instructions Manual for Microscope Olympus U-FH. Olympus U-FH 36 pages. Motorized illumination system with motorized focusing unit
OPTICAL CHARACTERISTICS «UIS2 Series»
-- The UIS series objectives that are not mentioned below can also be mounted on this microscope. --
The table below shows the optical characteristics of different eyepiece
and objective combinations. Objective specifications are marked on
the objective (as shown in the diagram on the right).
NOTE
Refer to the latest catalogue or consult Olympus for the updated infor-
mation on the eyepieces and objectives that can be combined with
this unit.
Series
MPLN
UIS2
Plan Achromat
series
(FN22)
MPLN-BD
Brightfield/
darkfield
Plan Achromat
(FN22)
MPLFLN
Plan Semi-
Apochromat
(FN26.5)
*1.25X:FN22
MPLFLN-BD
Brightfield/
darkfield
Plan Semi-
Apochromat
(FN26.5)
MPLFLN-BDP
Reflected Polarized
Light Plan Semi-
Apochromat
(FN26.5)
LMPLFLN
Long-WD Plan
Semi-Apochromat
(FN26.5)
LMPLFLN-BD
Brightfield/darkfield
long-WD Plan Semi-
Apochromat
(FN26.5)
SLMPLN Super-
long-WD Plan
Achromat (FN26.5)
Note) When an MPLN-BD series objective is used in darkfield observation with a xenon light source, the peripheral area
may be obscured with certain specimens.
20
Optical
characteristics
Magnifi-
N.A.
cation
Marking
5X 0.10
MPlanN
10X 0.25
20X 0.40
50X 0.75
100X 0.90
5X 0.10
MPlanN-BD
10X 0.25
20X 0.40
50X 0.75
100X 0.90
1.25X 0.04
MPlanFLN
2.5X 0.08
5X 0.15
10X 0.30
20X 0.45
50X 0.80
100X 0.90
5X 0.15
MPlanFLN-BD
10X 0.30
20X 0.45
50X 0.80
100X 0.90
150X 0.90
5X 0.15
MPlanFLN-BDP
10X 0.25
20X 0.40
50X 0.75
100X 0.90
5X 0.13
LMPlanFLN
10X 0.25
20X 0.40
50X 0.50
100X 0.80
5X 0.13
LMPlanFLN-BD
10X 0.25
20X 0.40
50X 0.50
100X 0.80
20X 0.25
SLMPlanN
50X 0.35
100X 0.60
Magnification
UIS marking
Cover glass thickness
—: May be used with our with-
out a cover glass.
0: Used without a cover glass.
Cover
glass
Resolu-
W.D.
thick
tion
(mm)
ness
Total
(μm)
(mm)
mag.
20.0
—
3.36
10.6
—
1.34
100X
1.3
0
0.84
200X
0.38
0
0.45
500X
0.21
0
0.37
1000X 0.73
12.0
—
3.36
6.5
—
1.34
100X
1.3
0
0.84
200X
0.38
0
0.45
500X
0.21
0
0.37
1000X 0.73
3.5
—
8.39
12.5X 870
10.7
—
4.19
20.0
—
2.24
11.0
—
1.12
100X
3.1
0
0.75
200X
1.0
0
0.42
500X
1.0
0
0.37
1000X 0.73
12.0
—
2.24
6.5
—
1.12
100X
3.0
0
0.75
200X
1.0
0
0.42
500X
1.0
0
0.37
1000X 0.73
1.0
0
0.37
1500X
12.0
—
2.24
6.5
—
1.34
100X
3.0
0
0.84
200X
1.0
0
0.45
500X
1.0
0
0.37
1000X 0.73
22.5
—
2.58
21.0
—
1.34
100X
12.0
0
0.84
200X
10.6
0
0.67
500X
3.4
0
0.42
1000X 0.87
15.0
—
2.58
10.0
—
1.34
100X
12.0
0
0.84
200X
10.6
0
0.67
500X
3.3
0
0.42
1000X 0.87
25.0
0
1.34
200X
18.0
0
0.96
500X
7.5
0
0.56
1000X
Eyepieces
WHN10X (FN22)
SWH10X (FN26.5)
Depth
Field
Total
of focus
of view
mag.
(μm)
(mm)
50X
98
4.4
18
2.2
6.1
1.1
—
1.4
0.44
0.22
50X
98
4.4
18
2.2
6.1
1.1
—
1.4
0.44
0.22
17.6
—
25X 220
8.8
25X 220
50X
59
4.4
50X
15
2.2
100X
5.2
1.1
200X
1.3
0.44
500X
0.22
1000X 0.73
50X
59
4.4
50X
15
2.2
100X
5.2
1.1
200X
1.3
0.44
500X
0.22
1000X 0.73
0.6
0.15
1500X
50X
59
4.4
50X
18
2.2
100X
6.1
1.1
200X
1.4
0.44
500X
0.22
1000X 0.73
50X
70
4.4
50X
18
2.2
100X
6.1
1.1
200X
2.5
0.44
500X
0.22
1000X 0.87
50X
70
4.4
50X
18
2.2
100X
6.1
1.1
200X
2.5
0.44
500X
0.22
1000X 0.87
11.4
1.1
200X
4.2
0.44
500X
1.3
0.22
1000X
Objective series
(PL = Plan)
NA (Numerical Aperture)
Brightfield/darkfield
application
FN (Field Number)
Depth
Field
of focus
of view
(μm)
(mm)
—
—
—
—
—
—
10.6
59
5.3
15
2.65
5.2
1.33
1.3
0.53
0.27
59
5.3
15
2.65
5.2
1.33
1.3
0.53
0.27
0.6
0.18
59
5.3
18
2.65
6.1
1.33
1.4
0.53
0.27
70
5.3
18
2.65
6.1
1.33
2.5
0.53
0.27
70
5.3
18
2.65
6.1
1.33
2.5
0.53
0.27
11.4
1.33
4.2
0.53
1.3
0.27