Fig.7
Move the brackets (QTY 6) away from
the granite
Fig.9
Loosen the set screw first then lower the
vertical pusher down
3.5

Level the machine

1. Once the machine is located in place on the fab floor, place a steel plate under each leveling leg
and lower the legs until they just touch the plate. See figure 10.
2. Put a level on the granite and adjust the leveling legs up and down until the granite is level left to
right and front to back.
Fig.8
Loosen the lateral pusher (QTY 8) until it is
no longer touching the granite
Vertical Pusher
Set Screw
5