Alphalux SureScan ALXPIR Instructions - Page 3

Browse online or download pdf Instructions for Accessories Alphalux SureScan ALXPIR. Alphalux SureScan ALXPIR 4 pages. 10a, 240v, 10 metre range

AUTOMATIC OPERATION (sensor driven):
To put the unit into automatic sensing mode.
1. Turn the light power switch off for approx 5 seconds and then turn back on.
The floodlight will illuminate immediately and remain on for the pre-set time period as described above.
Once the pre-set time period has elapsed the lamps will go out and the unit will then operate automatically
as per the presets described above.
MANUAL OPERATION (sensor override):
The unit is assumed to already be in the automatic mode as described above and the light switch
is in the 'ON' position.
To change from automatic to manual at any time during the day or night:
1. Turn the light switch off and immediately back on within one second.
2. The unit is now in manual mode and the light will remain ON continuously.
3. To return to automatic mode follow the instructions for Automatic Operation.
Note: To turn the floodlight off completely, simply turn off the wall light switch.
To return to 'automatic Operation' mode repeat the above instructions if required.
Technical Specifications
Characteristic
Rated Voltage
Rated Frequency
IP Rating
Time Adjustment
Sense Adjustment
Lux Adjustment
Maximum Load
Weight
Mounting Hole Centres
Load Cables (Red & Black)
Power Supply (Brown & Blue)
Safety Standards
Certifications
Symbols
Rating
240 V +/- 10%
50/60Hz
IP66 (with supplied mounting box)
5 Seconds to 7 minutes
0 to 10 metres @ 180 degrees
Full daylight to darkness
2400 Watts (resistive)
311 Grams
84mm Surface mounting
90mm Using mounting box
AWG 18 Rated to 105C
0.75mm ² Rated to 105C
AS/NZS 60598
AS/NZS 60529
CISPR15
ISO 9001 QA Procedures
1m
MOUNTING BOX INSTALLATION
Where the installer requires additional space or wishes to create a continuous conduit path, the sensor can
be mounted to the supplied matching mounting box. See diagram below for the mounting method.
Note: Under this method, the supplied mounting box screws must be used to secure the light base
to the mounting box.
Terminal
Sensor Head
Cover
Mounting
Screw
TYPICAL MOUNTING BOX INSTALLATION
POSITIONAL ADJUSTMENTS:
SENSOR HEAD ADJUSTMENTS
The sensor head can be adjusted by three methods:
1. Ball joint adjustment - The sensor head can be raised, lowered, or rotated on its base by the ball joint.
In most cases, fine tuning can be done with this method.
2. Knuckle adjustment - Allows greater movement, in all directions when used with the lock nut adjustment.
3. Lock nut adjustment - Spin the sensor clock or anti-clockwise or remove and reposition the entire head
into one of three openings for maximum directional flexibility.
It is important that the sensor head lock nut and knuckle screw are sufficiently loose prior to making
2 adjustments and re-tightened on completion.
Rubber Seal
Wall Plugs
where
required
(drill hole
0 6mm)
Mounting Box
(Supplied)
Mounting
Screw
Mounting Surface