INSTALLATION
Packing list
Unpacking
Remove the machine from the crate.
Check for hidden damage. If damage is found, notify the carrier responsible and the manufacturer
immediately.
Remove all packing material insulation and tape from the main unit.
Picking a suitable location
A 100mm hose connection is provided to vent the solvent vapours to the out-of-doors. Connect the hose
to an inline fan with a minimum extract capacity of 200m
booster blower for every 10m of hose or to keep the hose length as short as possible. If possible, locate
the machine by the outside wall.
The machine extraction system serves two purposes:
1. It purges the cleaning area of any airborne dust/contaminants that may otherwise be deposited on
the clean film.
2. It extracts any vapour from the cabinet and prevents any build-up of potentially flammable fumes.
If the operating personnel are present in the room during cleaning, and the room is sealed, it is
recommended that the room be well ventilated. It is suggested that the air be exchanged with fresh air
eight (8) times per hour or more. Contact the manufacturer for further information and help in this regard.
The machine has been designed with ease of installation in mind. The shipping crate will fit through a
standard door and accepts a standard pallet truck.
Installing the user interface box
1. Unpack the touchscreen interface box (packed inside of the machine).
2. Undo three (3) Allen bolts located on top of the stainless steel frame.
3. Place the touchscreen bracket on top of the stainless steel frame and secure it with (3) Allen bolts
removed in step 2.
4. Plug in the control cable in the socket located on the top cover.
Making the electrical connection
Make sure your local line voltage matches the nominal voltage of the BSF HYDRA CLEAN.
Connect the power cord to the appropriate source of AC power. Provide a line fused for rated current or
more. An electrical outlet (Mains) must be provided no further from the machine than the reach of the
power cord. If you must use an extension cord, use one that has earthing contacts in it and is rated for a
load current of twice the rated current or more.
Main unit BSF HYDRA CLEAN
Buffer Rollers
Filler, reservoir, 100 mL
35 mm rollers
8/16mm rollers (if specified at order)
Touchscreen display
Power cord
Wi-Fi dongle (if specified at order)
3
per hour. It is good practice to utilize one
1
16
1
10
10
1
1
1
Page 5 of 20