AccuPower IQ-338 User Manual - Page 4
Browse online or download pdf User Manual for Battery Charger AccuPower IQ-338. AccuPower IQ-338 7 pages.
Also for AccuPower IQ-338: User Manual (6 pages)
You can choose the following programs:
Charge
In this program you can charge the inserted batteries.
Charge Test
With „Charge Test" program you can measure the charged capacity of the batteries. The
charger discharges the batteries in the first step, during the discharge process the LC
Display starts to count the discharged capacity. After that, the battery gets charged
nd
completely in the 2
charger's memory and can be retrieved after finish. So this test consists of the following
steps:
1) Discharge (The capacity gets measured and stored and is available after end of the
test)
2) Charge (The capacity gets measured and stored and is also available after end of
the test)
If the channel button gets pressed for the first time, only the display lights up. After
pressing it again, the shown capacity on the display switches between the measured
charging and discharging capacity. Which one of them is displayed, is symbolized by
the label "CH" for charged and "DISCH" for discharged value over the unit "mAh". Also
the current is changing depending on the chosen current during the Charge Test. The
used charging current is symbolized by „CH-CURRENT" as well as the discharging
current by „DISCH-CURRENT".
Generally, the charging capacity value can be different to the discharging capacity
value because of efficiency of the chemical reaction in the batteries.
This mode can also be used very well for refreshing batteries.
Discharge Test
The difference of „Discharge Test" program to „Charge Test" program is, that the batteries
will get charged in the 1
This happens in the 2
completely again in the 3
1) Charge (This capacity gets measured and displayed but not stored till the end)
2) Discharge (The capacity gets measured and stored and is available after end of the
test)
3) Charge (The capacity gets measured and stored and is also available after end of
the test)
User Manual
step. Both capacity values (discharged as charged) are stored in the
st
step so that it can be discharged afterwards with the full capacity.
nd
step. To complete the process, the battery gets charged
rd
step. The process is as follows:
4/7
Update version-V2