ACCUR8 CO2-6000 User Manual - Page 7

Browse online or download pdf User Manual for Monitor ACCUR8 CO2-6000. ACCUR8 CO2-6000 13 pages. Co2 monitor with temperature & humidity

ACCUR8 CO2-6000 User Manual
17.

Specifications

Typical test conditions: Ambient Temp: 23 ± 3°C, Humidity = 50%-70%, Altitude = 0-100 metres
Operating Temperature
Storage Temperature
Operating & storage Humidity
CO2 Measurement
Measuring range
Display resolution
Accuracy
Temperature compensation
Response time
Warm-up time
Temperature Measurement
Operating temperature
Display resolution
Response time
Humidity Measurement
Measuring range
Accuracy
Display resolution
Operating Voltage
Dimensions
Weight
32°F - 122°F (0°C - 50°C)
14°F - 140°F (-10°C - 60°C)
0-95% (non-condensing)
(0-5000)ppm
1ppm (0-1000); 5ppm (1000-2000); 10ppm (>2000)
(0-3000)ppm: ± 50ppm ± 5% of reading. (>3000)ppm: ± 7% of reading
±0.2% of reading per °C (reference of 25°C)
<2 minutes for 63% of step change or< 4.6 min for 90% step change
<20 seconds
32°F - 195°F (0°C ~90°C)
0.1°F (0.1°C)
<20 minutes (63%)
5-95%
±5%
1% Main interface display, 0.1% Max/Min display
DC(5±0.25)V
120*90*35mm
170g device only
7