4.2.4. User interface
4.2.4.1 testing program - self test – after connecting to the network all led lights will light up at the preset
sequence with the aim of checking all functions as well as the presence of required elements.
After the self test, if operating conditions are met, the thermostat will activate the
the indicator (4).
If all led lights are flashing simultaneously, there is a problem with the temperature sensor
function. It is necessary to check the connection between the heating element and the
thermostat.
4.2.4.2 Sensors – contactless controls (5, 6)
Touching the marked spot of the sensor with your thumb, you will activate the following functions:
-ON
: keep your thumb on the sensor for 4 s to turn the QS on
-OFF
:if the QS is in the ON and/or TIME mode keep your thumb on the sensor for 4 s to turn the QS
off
- touching the same sensor for 1 s, the preset temperature will change in cycles ranging from
- touching the
sensor for 3 s the heating period will be activated in fixed duration of 2 hours at the
preselected temperature
4.2.4.3 Heater function indicator - Illuminated line at the bottom of the thermostat housing (3)
4.2.4.4 Displaying the temperature with elliptical indicator (4)
Indication levels
-
blue – temperature up to 20°C
green – radiator temperature 40°C, 50 °C
-
red – temperature up to 55°C, 65°C.
-
flashing red light – radiator temperature exceeds 65 degrees, possible radiator overheating
-
(5°C) and
to 65° С