Accurate Technology DigiStop-10 Installation & Operation Manual - Page 13
Browse online or download pdf Installation & Operation Manual for Measuring Instruments Accurate Technology DigiStop-10. Accurate Technology DigiStop-10 20 pages. Digi-stop series
Auto on/off
To prolong battery life, the Readout has a built-in function that turns off the
Readout after a period of no movement or key activity. The Auto On/Off
function is programmable from 0 (always on), to 240 (minutes) before entering
sleep mode.
Press the
/
key or move the measurement system to wake up the
ON
OFF
Readout. Any key press or system motion while the Readout is awake restarts
the Auto On/Off timer.
See Section 3: Readout Programming,
Programming Parameter Pr12.
Making Incremental Measurements
The Digital Readout has two measurement modes, or indexes. One is referred
to as ABS or Absolute, and the other as INC, or Incremental. The absolute
measurement mode allows the operator to read the current position of the Stop
referenced from a fixed or known position such as the saw blade.
The incremental mode allows the operator to make relative distance
measurements from one arbitrary point to another. The absolute position of
the Stop is not lost when using the incremental mode.
Absolute
The readout automatically enters ABS mode when power is first
applied. This is indicated by the ABS symbol in the upper left corner of the
display. While in the ABS mode, all fence positions are related to the current
ABS, or absolute system reference point, ie the blade.
Incremental
To enter the INC mode, press and hold the
key for
UNITS
approximately 3 seconds. The INC symbol will appear in the upper left corner
of the display. When the INC mode is entered the readout will display zero (0)
or the last offset if one was entered, and may be changed by using the
+
or
-
keys to provide a different offset. Moving the Stop in either direction will display
the distance moved from the initial INC starting point (plus any offset). To
complete another incremental measurement from the new position,
momentarily press the
key. The readout will again change to 0 (or the
UNITS
previously programmed offset). To return to the ABS mode, press and hold the
key for approximately 3 seconds.
UNITS
NOTES: When the readout is in incremental measuring mode the
key no
UNITS
longer functions to change the measurement units displayed.
The absolute position of the Stop is not lost when using the incremental mode.
When the readout is switched back to the absolute mode the readout reflects
the current Stop position relative to your original calibrated setting.
Accurate Technology Digi-Stop
Page 13 of 20