Accurate Technology ProScale 18W User Manual - Page 18
Browse online or download pdf User Manual for Scales Accurate Technology ProScale 18W. Accurate Technology ProScale 18W 20 pages.
The Digital Readout Programming Parameters are listed below.
Values in [ ] are the range of values available for that Parameter.
Factory defaults values are shown in
Pr 1 – Datum Key
The programmed value that will be recalled whenever the Datum key is
pressed during normal operation.
Default = 0.00
Pr 2 – Direction of Travel
This parameter controls the sign of travel (positive vs. negative) when the
measuring system is moved.
Default = 0
Pr 3 – Key Lockout
This parameter controls the operation of the +,
(set to 1), these keys will not function and the
display. This prevents accidental changes when depressing these keys
during normal operation.
Default = 0
Pr 4 – Display Resolution
This parameter sets the number of places to the right of the decimal point on
the display. When the DRO is in a decimal mode (in, mm or cm), it will auto-
range to the next resolution if the value is too large to be displayed in the
current resolution but is displayable in an alternate resolution.
A value of 1 will display x.x.
A value of 2 will display x.xx
A value of 3 will display x.xxx
Default = 3
•
This programming option has no effect when displaying fractions.
Pr 5 – Movement for Auto-On function
This parameter sets the amount of encoder, or system, movement required
to automatically wake up the digital readout when it is turned off.
Default = 0.1mm
Manual Part # 800-1405-001, Rev A
Bold Red.
[0
to + 999.999in] or
-
LOCK
LOCK
LOCK
LOCK
[0
to +9999.99mm]
[0
or 1]
[0
or 1]
and
keys. If enabled,
DATUM
symbol will appear on the
[1, 2,
3
[0.3 to 10mm]
Page 18 of 20
]