Arcam SA10 Custom Installation Notes - Page 17
Browse online or download pdf Custom Installation Notes for Amplifier Arcam SA10. Arcam SA10 20 pages. Ip/serial programming interface and ir remote control commands
Processor mode volume (0x5C)
Set the processor mode volume
Example
Command/response sequence to set the processor mode volume to 45
(0x2D).
Command:
0x21 0x01 0x5C 0x01 0x2D 0x0D
Response:
0x21 0x01 0x5C 0x00 0x01 0x2D 0x0D
System status (0x5D)
Request the system status.
Example
Command/response sequence to request the system status.
Command:
0x21 0x01 0x5D 0x01 0xF0 0x0D
Response:
0x21 0x01 0x5D 0x00 0x01 0xF0 0x0D
Note:
This command will return the following information about the system:
•
Power state
•
Brightness level
•
Headphone status
•
Software version
•
Model Number
•
Volume setting
•
Mute status
•
Current input source
•
Headphone override status
•
Balance setting
•
Sample rate
•
Network name
•
IP address
•
Timeout counter value
•
Lifter temperature (SA20 only)
•
Output temperature
•
Auto shutdown status
•
Input detect status
•
Processor mode input
•
Processor mode volume
•
DC offset status
•
Short circuit status (SA20 only)
•
DAC Filter
COMMAND:
Byte:
Description:
St
0x21
Zn
Zone number
Cc
0x5C
Dl
0x01
Data
0x00 (0) – 0x63 (99) – Set the volume
0xF0 – Request the current volume
Et
0x0D
RESPONSE:
Byte:
Description:
St
0x21
Zn
Zone number
Cc
0x5C
Ac
Answer code
Dl
0x01
Data
0x00 (0)– 0x63 (99)
Et
0x0D
COMMAND:
Byte:
Description:
St
0x21
Zn
Zone number
Cc
0x5D
Dl
0x01
Data
0xF0 – Request the system
Et
0x0D
RESPONSE:
Byte:
Description:
St
0x21
Zn
Zone number
Cc
0x5D
Ac
Answer code
Dl
0x01
Data
0xF0 - System status sent
Et
0x0D
17