3.2. Symptom: Console not switched on.
Remove the console plastic cover and check if
12DC input exists on console PCB or not.
Document: Service Manual
Description:
Page: 19 of 20
Check if 12DC output exists on EMS
controller or not.
No
Replace
EMS
controller
Elliptical/Upright Bike/ Recumbent Bike
No
Yes
Replace
12DC power
cord
19
Model:
E7/B8/R8,
E Plus
Yes
Replace
console PCB