3.3
Technical Data
Technical Data
Intended use:
Supply voltage:
Power consumption:
LED:
Inputs:
Valve outputs:
Valve voltage:
Valve current:
Fuse:
Electrical connections:
Operating temperature:
Designs:
Connection set (option):
Subject to technical changes.
12
-solenoid valve controller for cleaning industrial filtration plants
-100...240 V AC, 50...60 Hz
-24 V DC ± 10% (option) (safety extra-low voltage SELV)
30 VA, self-consumption about 3 kW
- HE 5710: 4 for valve control, red
- HE 5711: 8 for valve control, red
-RUN, green
-PULSE, yellow
-TEST, green
-START: start cleaning (contact closed)
-START CYCLE: cycle cleaning (trigger signal), switchable with a
potential-free contact or semiconductor switch, "Active Low"
- HE 5710: 1...4
- HE 5711: 1...8
24 V DC ± 10%
-1 A for a pulse time ≤ 1s and a pause time ≥ the pulse time
-The outputs are short-circuit-proof
Glass fuse 5 × 20 mm, 2 A, slow-bow
Vertical cage spring release terminals
-20°C...+50°C
-20°C...+40°C in EX zone
- Assembly on standard rail support: 165 mm × 111 mm (W × H)
-dust-proof Makrolon housing (IP65) with transparent cover, with a
M25 × 1.5 thread and two M32 × 1.5 threads for metric screw
connections
-If necessary, openings should be closed with screw plugs, to
make the device dust-proof (IP65)
-An M32 screw plug is in the scope of delivery of HE 5710
Housing dimensions: 180 mm × 130 mm × 78 mm (W × H × D)
-1 × M25 screwed cable gland
-2 × M32 screwed cable gland
-Multiple sealing inserts and locking bolts
-Height of the cable gland: 40 mm
HE 5710 / 5711 Operating Instructions
# 371814 | Version 1.4