8.
Operational Approach
1. [Weighing Mode]:
Under weighing mode, press 【 MODE 】 key to enter counting mode.
UNIT SELECT: Press 【UNIT】 key to select the weighing unit of KG or LB, the corresponding indicator
will appear on the display screen.
TARE:Place the items on the scale plate which need to removed the tare weight, then press
【TARE】 key, the 'WEIGHT' window displays '0' and the 'TARE' indicator light is on; At this point,
remove the item has been tared from the scale plate, the 'WEIGHT' window displays a negative
number, press【TARE】key again, the 'WEIGHT' window displays '0',and the 'TARE' indicator light
is off.
ZERO:In the process of using, if there is a zero shift phenomenon appears, that is, there is nothing
on the scale, but there will be a weight display in the 'WEIGHT' window. The weight could displays
'0' by pressing 【ZERO】key.(Zeroing range: ≤ 4%FS, For example, a 300 kg scale can only be tared
≤12 kg weight).This function is not available in the TARE mode.
2. [Counting Mode]:
Under counting mode, press 【 MODE 】 key to enter percentage mode.
In counting mode, press 【 SETUP 】 key to start weight sampling, the 'WEIGHT' window displays
'SAPX', X is the number of samples. Press 【 ↑ 】 key, screen will display '10,20,50,100,200,500,1000'
seven sampling number in turn. Press【TARE】key, confirm the sampling number.
After selecting the number of samples, the 'WEIGHT' window displays 'LOAD-C', put the same
number of samples on the scale plate, and press【TARE】key to complete the sampling.
Under sampling mode, press 【 SETUP 】 key to exit sampling mode.
3. [Percentage Mode]:
Under weighing mode, press 【 MODE 】 key to enter weighing mode.
In percentage mode, the indicators of 'KG','LB','PCS' are all off.
Press 【 SETUP 】 key and the 'WEIGHT' window displays 'LOAD-P'. There are two ways to sample
the weight: